urmet domus DS1092-004 Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AUTO-IRIS PLUG
Auto-Iris plug PIN definition
PIN
VIDEO
DC 12v
1
NC
2
IRIS
DRIVER (+)
3
GND
4
AUTO-IRIS LENS FOCUSING PROCEDURE
1.
Fit the optics on the camera.
2.
Position the VIDEO/DC switch according to the lens employed.
3.
Connect the wire to the Auto-Iris connector.
4.
Position the AGC switch to NOR.
5.
Turn the LEVEL trimmer to H until the picture is white.
6.
Position the ES switch to ES: the picture appears out of focus.
7.
Adjust the focus.
8.
Position the ES switch to NOR: the picture can be white.
9.
Turn the LEVEL trimmer to L until the picture appears well lit.
10.
Position the AGC switch to AGC.
11.
Turn the back-focus adjustment ring and repeat the operation from point 4 if focus is not correct.
DS1092-004
1
DC
DAMP (-)
DAMP (+)
DRIVER (-)
2
IMPORTANT:
consumption of 50 mA.
Urmet series 1090 AUTO-IRIS DC DRIVER lenses may
3
be directly connected to the camera.
Shift the wire from pin 2 to pin 3 on the lens
connector if a Urmet Domus 1090 AUTO-IRIS VIDEO
DRIVER lens is used.
4
Lenses
must
have
a
maximum
9

Publicidad

Tabla de contenido
loading

Tabla de contenido