Technical specification
Instead of using mains electricity, Zero Client DZ22-2 can be powered via
the Ethernet cable (Power over Ethernet, PoE).
Note that your network infrastructure must be set up for this.
Make sure that only 8-core Gigabit Ethernet cables of at least category 5
(Cat-5) are used. Power is supplied via all 8 cores.
Make sure the supply is sufficient to power your Zero Client DZ22-2, even over long
distances of up to 100 metres. Fujitsu Technology Solutions recommends that you
only use approved Ethernet power supplies that meet the following specifications:
Rated voltage: 55 V
Rated power: 60 W
Conforming to IEEE802.3at.

Preset operating modes

The picture position and size have been set to optimum values at the factory for
the operating modes listed above. You can modify and save the settings (see
chapter
For ergonomic reasons, we recommend a screen resolution of 1680 x 1050
pixels (Zero Client DZ22-2) or 1280 x 1024 pixels (Zero Client DZ19-2). Because
of the technology used (active matrix), an LCD monitor provides a totally
flicker-free picture, even with a refresh rate of 60 Hz.
Most frequent operating modes
Horizontal frequency
37.9 kHz
48.4 kHz
63.7 kHz
65.0 kHz
Fujitsu Technology Solutions
"Changing the monitor settings", Page 20 - English
Refresh rate
60 Hz
60 Hz
60 Hz
60 Hz
Screen resolution
800 x 600
1024 x 768
1280 x 1024 (native Zero Client DZ19-2)
1680 x 1050 (native Zero Client DZ22-2)