Trouble shooting
Fault
Compressor not working.
Compressor is working but
there is no pressure.
Compressor is working,
the pressure gauge shows
pressure but the tools are
not working.
80
Possible cause
• No mains voltage.
• Mains voltage too low.
• Outside temperature too
low.
• Motor overheated.
• Check valve is leaking
• Seals are damaged
• Hose connections are
leaking.
• Quick-action coupling is
leaking.
• The pressure set on the
pressure regulator is too low.
Remedy
• Check cords, power plug,
fuse and power outlet.
• Avoid extension cords that
are too long. Use extension
cordsthat have an adequate
core cross section.
• Do not operate at outside
temperatures below +5°C.
• Allow the motor to cool
down, where necessary
remove the cause of any
overheating.
• Replace the check valve
• Check the seals, have
defective seals repaired
by an approved specialist
workshop.
• Check the pressure
hose and tools, replace if
necessary.
• Check the quick-action
coupling, replace if
necessary.
• Open the pressure
regulator more.