FEATURES:
• Factory preset address for the locomotive is 03.
• 40 khz frequency for a smoother motor control.
• The V.4 decoder supports DCC, Motorola, DC, AC and Marklin® digital systems.
• 14, 28 or 128 selectable speed steps for DCC systems.
• Load compensation function.
• Outputs overload protection for all functions.
• Audio amplifi er 2W 4 Ohms.
DECODER PARAMETERS ADJUSTING:
The V.4 Loksound decoder (32 Mbit) controls several parameters. You can fi nd a list of the most important
ones at the end of this instructions. Each parameter (CV) can be confi gured independently using its respective command.
DCC Systems (Lenz, Intellibox, etc.)
It is much easier to modify the parameters if you have a DCC compatible digital system or an Intellibox. Please, read the corresponding chapter in your system manual (DCC decoders
programming). The V.4 Loksound decoder support any NMRA programming system.
ANALOG OPERATION
When using conventional transformer, the locomotive movement will be similar to that of a locomotive without a decoder. The locomotive will only start its running when receiving a minimum
voltage between 5.5 and 6 volts, as the decoder will not work with a lower tension. Please note the following warnings: The decoder installed in your Rivarossi locomotive has been specifi cally
adapted for this model and it should be used only in this particular model. Always disconnect the decoder from the power supply before doing any work on it.
If removing the speaker were necessary for maintenance purposes, please handle it very carefully.
Do not put any pressure on it or touch the speaker membrane.
The reset function is very convenient, as you can set the original factory values again at any time. You can use this function with DCC and Motorola systems. To use this function, type "8" in CV 8
or "08" in register "08".
Adjust the sound volume.
The lokSound allows the individual volume control of each sound. Please refer to the following table to see which CV you need to change:
KEY
FUNCTION
SOUNDSLOTS
VOLUME CVs
F0
Front lights
F1
Sound on/off
1, 2, 18
259, 267, 395
F2
Bass tone horn
3
275
F3
High tone / Bass tone signal
6
299
F4
Stationmaster
11
339
F5
Rheostatic brake off
F6
Main light
F7
Red light
F8
Rheostatic brake
10
331
F9
Compressor
8
315
F10
Special attention
5
291
F11
High tone whistle
4
283
Before you change any of the volume control CVs, please make sure that the CV 31 is set to 16 and CV 32 = 1! These two CVs are used as index selection registers to distinguish between the real function of
CV 257-511.
F19 Solo funcionara cuando F6 este apagado
The master volume control CV 63 controls all sound effects. The resulting sound volume for each individual sound effect therefore is a mixture of the master volume control settings and the individual volume control sliders.
CV
NAME
DESCRIPTION
1
Loco address.
Locomotive address
2
Start voltage.
Sets the minimum speed of the engine
3
Acceleration.
This value multiplied by 0.869 is the time from stop to maximum speed.
4
Deceleration.
This value multiplied by 0.869 is the time from maximum speed to stop.
5
Maximum speed.
Maximum speed of engine
6
Medium speed.
Averall engine speed
8
Manufacturer's ID.
Manufacturer's ID (ESU). Set CV8 to value 8 for automatic resetting.
13
Analogue mode F1-F8.
Status of functions F1 to F8 in analogue mode.
Bit
Function
0
F1
1
F2
2
F3
3
F4
4
F5
5
F6
6
F7
7
F8
17
Extended address
Extended engine addresslng address of engine
18
HORNBY HOBBIES LTD, (UK)
HORNBY ESPAÑA S.A,
Westwood Industrial Estate,
Federico Chueca, s/n
Margate, Kent, CT9 4JX
28806 Alcalá de Henares
Electric locomotive RENFE 251
When programming using Lenz, Uhlen-
brock or Arnold equipment, please refer to
their programing instructions. If the error
message "err02" is displayed during pro-
Resistance 47
gramming with Lenz or Arnold equipment,
a 47 Ohmresistor (0.5) Watt or higher)
must be inserted between one of the two
Central unit
supply cables and the programming track.
Programming track
VALUES
KEY
FUNCTION
SOUNDSLOTS
F12
Short horn
13
100, 110, 128
F13
Short whistle
12
128
F14
Curve squeal
15
128
F15
Rail clank
20, 21
128
F16
Coupling/Uncoupling
7
F17
Sanding
14
F18
Brake realease
16
F19+F6 OFF
Low beam / high beam
110
F20
Acceleration, Shunting mode
95
F21
Open/Close door
19
128
F22
Up/Down pantograph
9
128
RANGER
1-127
1-75
0-255
0-255
0-64
0-64
0-255
Value
1
2
4
8
16
32
64
128
HORNBY ITALIA S.r.l,
HORNBY FRANCE SAS,
HORNBY DEUTSCHLAND GmbH,
via Ferri, 14
Parc d'activites de Gomberville,
Ostpreußenstrasse 13,
25010 Borgosatollo
F-78114 Magny les Hameaux
96472 Rödental
27
Brake modus
28
RailCom® confi guration
29
Confi guration register
31
Index register H
32
Index register L
49
Extended confi guration
VOLUME CVs
VALUES
355
128
347
128
371
128
411, 419
128, 128
307
128
363
95
379
70
50
Analogue mode
403
128
323
128
52
Load control parameter
«K» for slow driving
53
Control Reference voltage
54
Load control parameter K
55
Load control parameter I
56
Operating range of load
control
VALUE
63
Sound volume
3
124
Extended Confi guration #2
1
60,15seg
48-12seg
155
151
1
125
Starting voltage
Analog DC
126
Maximum speed
Analog DC
127
Starting voltage AC
128
Maximum speed
Analog AC
192
128
www.hornbyinternational.com
Allowed brake modus
Bit
Function
0
ABC brakes, voltage higher on right side
1
ABC brakes, voltage higher on left side
2
ZIMO HLU brakes active
3
Brake on DC, if polarity is vice-versa to the driving direction
4
Brake on DC, if polarity is the same as driving direction
Settings for RailCom®
Bit
Function
0
Channel 1 given free for address broadcast
1
Data connection on channel 2 allowed
7
RailCom® Plus automatical loco registration active
The most complex CV within the DCC standards. This register contains important information, which is only relevant in DCC mode.
Bit
Function
0
Normal direction of travel.
Forward becomes reverse.
1
14 speed steps (only in DCC mode).
28 or 128 speed steps (only in DCC mode).
2
Analogue mode off.
Analogue mode permitted.
3
RailCom® switched off
RailCom® allowed
4
Speed curve through CV 2, 5, 6.
Speed curve through CV 67 - 96V.
5
Short addresses (CV 1) in DCC-mode.
Long addresses (CV 17+18) in DCC-mode
Selection page for CV257-512
Selection page for CV257-512
Activate support for brake sections or switch off Back EMF control
Bit
Function
0
Load control off
Load control activated
1
DC motor PWM frequency - 15 kHz pulse frequency
DC motor PWM frequency - 30 kHz pulse frequency
2
Märklin® delta mode - Delta mode off
Märklin® delta mode - Delta mode on
3
Märklin® second address off
Märklin® second address on
4
Automatic speed step detection
DCC speed step detection off
5
Disable LGB® function button mode
Enable LGB® function button mode
6
Disable Zimo® Manual Function
Enable Zimo® Manual Function
Selection of allowed analogue modes
Bit
Funzione / Funktion / Function
0
Disable AC Analog Mode
Enable AC Analog Mode
1
Disable DC Analog Mode
Enable DC Analog Mode
"K"-component of the internal PI-controller for the low speed steps. Defines the effect of load control. The higher the value, the stronger the
effect of Back EMF control.
Defi nes the Back EMF voltage, which the motor should generate at maximum speed. The higher the effi ciency of the motor, the higher this
value may be set. If the engine does not reach maximum speed, reduce this parameter.
"K"-component of the internal PI-controller. Defines the effect of load control. The higher the value, the stronger the effect of Back EMF
control.
"I"-component of the internal PI-controller. Defines the momentum (inertia) of the motor. The higher the momentum of the motor (large
0 - 100% Defi nes up to which speed in % load control will be active.
A value of 32 indicates that load control will be effective up to half speed.
Volume of running and additional sounds.
Additional important settings for LokSound Decoders
Zusätzliche wichtige Einstellungen der LokSound-Decoder
Bit
Function
0
Disable driving fi rection
Bi-directional bit: Enable driving direction when shifting direction
1
Disable decoder lock with CV 15/16
Enable decoder lock with CV 15/16
2
Disable serial protocol for C-Sinus
Enable serial protocol for C-Sinus
4
Adaptive regulation frecuency
Constant regulation frecuency
28
Value
1
2
4
8
16
131
Value
1
2
128
30
Value
0
1
Enabled
0
2
Enabled
0
4
Enabled
0
8
Enabled
0
16
Enabled
0
32
16
16
0, 2, 3
0
0 - 255
27
Value
0
1
0
2
0
4
0
8
0
16
0
32
0
64
0 - 3
03
Valore / Wert / Value
0
1
0
2
0 - 255
15
0 - 255
140
0 - 255
50
1 - 255
100
1 - 192
255
0-192
140
21
Value
0
1
0
2
0
4
0
16
0 - 255
90
0 - 255
130
0 - 255
90
0 - 255
130
Service Sheet ELBD-82
January 2015 - Subject to technical modifi cations