Instructions for Use and Installation HNS-M / HLS

Control panel functions

The steamer is started by pressing the ON-OFF button in the control centre. After that, the temperature display
starts to flash. The temperature may be set with the + and – buttons in one decree steps between 25°C – 50°C. If
the temperature on the display is correct, you can move to time display by pressing the OK button. When the
display flashes, you can adjust the time with the + and – buttons in one minute steps up to 90 minutes, after which
the display changes to the hour display, max. 4 hours.
When there is 90 minutes left, the display changes to minute display. Before that, only full hours remaining are
shown.
The last set temperature and time are stored in memory.
Lighting controls
Lights can also be controlled with the control centre button, which lights the led indicator lights by the push button.
The connectors LC1 and LC2 on the circuit board are for lighting control. External voltage is brought to the circuit
board 24 V DC max. 50 mA, connected to connector LC1. When the light button is pressed, the opto switch on
the circuit board transfers the voltage to connector LC2, which controls the actual lighting control unit. (Light
adapter 0043214)
Push button

Button function

When the steamer is started with the push button, it runs for 30 minutes. The led indicator light above the push
button lights. Steamer time cannot be adjusted, it stops automatically. Steamer can be stopped by pressing the
push button even before the time has run out, in which case the light turns off. Steamer can also be restarted, if
desired.
A separate limiter thermostat can be used with the steamer, if push the button controls are used. (Thermostat
0043210) The thermostat prevents the temperature in the steam room from raising above +50 °C.
See thermostat installation on the next page.
Alarms
Midi (RA 17) Control centre
E1 Water tap is closed when the steamer is started or running, or some other reason prevents water
from running into the steamer. Open the tap. If the malfunction is in the steamer, it may require service.
E2 Error message comes when serial traffic between the control centre and the circuit board is not working.
Troubleshooting requires service.
The steamer stop after the error message. Fix the cause of the malfunction or call service. Malfunction can be
confirmed with the ON – OFF button.
Push button led indicator light flashes rapidly in a steamer equipped with a push button, if there is a malfunction
in the steamer; steamer has been started with the water tap closed, or some other reason has prevented water
from running into the steamer. This notification appears when the steamer is running, if water intake is cut off.
The error message can be confirmed with the push button. Fix the malfunction or have it fixed.
The circuit board has an output for alarm 24 V DC max 50 mA. The output is activated when E1 or E2 error
message appears on the display or when the led on the push button flashes rapidly. The alarm is confirmed with
the ON - OFF push button.