Indicator lights
While the battery charge level is being displayed, the Indicator lights will also flicker briefly
with each energizer pulse in order to show that the energizer is still functioning. After 30
seconds, the Indicator lights revert to displaying the energizer output voltage. When set to
Battery indicator, the energizer pulses at Slow speed and delivers half energy at all times.
!
!
The battery indicator test is only relevant when a lead-acid battery is used.
Battery management
13.
Batteries contain harmful chemicals and when used incorrectly, may
cause injury. Observe the guidelines for battery care, maintenance
and safety in this manual and in the documentation supplied with
your battery.
Battery charging
he battery energizer is not rated for connection to mains-operated
or line-operated equipment. Ensure that the battery is disconnected
from the energizer before connecting the battery to any
mains-operated or line-operated battery charging device. Failure to
observe this precaution could result in damage to the energizer and
possible electrocution.
Battery-only installation
Excellent battery charge level (90-100%)
• No action required
Very good battery charge level (70-90%)
• No action required
Average battery charge level (40-70%)
• Monitor battery charge level
• Recharge the battery to avoid long-term damage to the battery
Poor battery charge level (20-40%)
• Monitor battery charge level
• Recharge the battery to avoid long-term damage to the battery.
Very poor battery charge level (0-20%)
• Recharge the battery immediately
53