4.2.6 RINSING THE CATALYTIC CONVERTER WITH HOT WATER

Rinsing the catalytic converter with water may be necessary in situations where steam cleaning do not remove
the particles or bad odours. This procedure requires heavy lifting and a facility where spillage of water is
acceptable. Make sure to perform steps 1.-4. in the "Cleaning the flue terminal" procedure and follow the steps as
follows.
1. Place the toilet where it is OK to spill water, e.g. where there is a suitable drain, outside or in a bath. Use the
specially designed Cinderella funnel, or a funnel that fits in the exhaust pipe. Slightly tilt the toilet forward,
and pour 2–3 L of hot water through the exhaust pipe and catalyst. The excess water should be clean at the
end of the rinsing process. If necessary, use more water to properly clean the system.
2. Reconnect the appliance to the flue pipe and power supply.
3. Install the ash container and front cover.
4. Perform the performance test as described in section 2.5
NOTE!
Before disconnecting the appliance and rinsing the system with hot water, inspect the
catalytic converter and perform steam cleaning in accordance with section 4.2.2. If the
catalytic converter is still clogged, or odour is still noticeable when incinerating, perform the
system rinsing in accordance with section 4.2.6
The front of the outer shell is thin and should therefore not carry the entire weight of the
toilet. Be careful not to break it while rinsing the catalytic converter.