* actual filter and UV lamp replacement periods may vary based on the environment in which the unit is used. More contaminated environments
will shorten filter life. Check filters regularly to ensure optimal operation of the unit
9. Disassembly
9.1. Front cover removal:
Using the included front panel removal tool, insert the tool into the top side air intake slot and push
towards the back of the unit until the front panel springs free. Repeat process for opposite side and
then pull the whole cover upwards to take to remove it and expose the filter compartment; see steps 1,
2 &3 below.
9.2. Prefilter removal:
After removing the front cover, turn the swivel tabs located in the 4 corners to release the prefilter; see
illustration 'A' below.
9.3. HEPA/Carbon filter removal:
After removing the Prefilter grasp the small pull tabs located on the top of the HEPA/Carbon filter and
pull hard towards you. You may have to pull several times to release the filter as it has a special
air-tight seal on the back edges which may provide resistance during removal; see illustration 'B'
below.
9.4. Ultraviolet Germicidal Lamp removal:
Grasp lamp gently by end caps and rotate the clockwise or anticlockwise until the bulb is loose in the
socket. Pull the bulb straight out towards you. DO NOT twist the bulb or put excessive force on the
glass or end caps as this may cause the bulb to break; see illustration 'C' below.
1
A
10. Assembly
10.1.
Ultraviolet Germicidal Lamp installation:
Grasping lamp gently by end caps, align pins with lamp holder socket and insert pins into socket.
Rotate the clockwise or anticlockwise until the bulb locks into place. DO NOT twist the bulb or put
excessive force on the glass or end caps as this may cause the bulb to break; see illustration 1 below.
2
B
C
10
3