When the power cord is damaged it must be replaced by the
manufacturer, Customer support Service or similarly qualified personnel.
Gas adjustment
• Take precautions on the operations and adjustments
carried out when converting from one gas to another.
• All work must be carried out by a qualified technician.
• Before you begin, turn off the gas and electricity supply to
the appliance.
1. Change the injector of the burners
Injector
2. Adjustment of minimum level of the flame
Control
handle
Tap
Sealing
ring
Built-in Gas Hob | Encimera Vitrocerámica Gas | Placa Vitro Gás
Remove the pan support, Burner lid and
Flame spreader.
Unscrew the injector using a 7 mm box
spanner and replace it with the stipulated
injector for a new gas supply. Carefully
reassemble the all components. After the
injectors are replaced, it is advisable to
strongly tighten the injector in place.
1. Turn the taps down to minimum.
2. Remove the knob from the tap and place
a small bladed screwdriver in the centre of
the tap shaft.