1. Wiring diagram
A. For power supply: 230V 50Hz
Distribution Box (Customer prepare)
Power Supply
230V 50Hz
Earthing
B. For power supply: 400V 50Hz
Distribution Box (Customer prepare)
Power Supply
400V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
For your safe use in winter, it's strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
2.Options for protecting devices and cable specification
MODEL
Rated Current A
Rated Residual Action
Breaker
Current mA
Fuse
A
)
2
Power Cord(mm
)
2
Signal cable(mm
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
increased. The signal cable can be extended to 50m at most.
Power Cord
Fuse
Breaker
Power Cord
Fuse
Breaker
AXR10V
AXR13V
AXR17V
12.0
15.0
30
30
12.0
15.0
3×2.5
3×2.5
3×0.5
3×0.5
3×0.5
- 14 -
For installers and professionals
Swimming Pool Heat Pump Wiring Board
Swimming Pool Heat Pump Wiring Board
AXR21V
AXR26V
19.0
22.5
25.5
30
30
30
19.0
22.5
25.5
3×4
3×4
3×6
3×0.5
3×0.5
>
AXR32V
AXR32VT
28.5
11.3
30
30
28.5
11.3
3×6
5×2.5
3×0.5
3×0.5
10m, wire diameter must be
AXR40VT
15.0
30
15.0
5×2.5
3×0.5