Initial Operation/Setting; Loading The Fuel Cell; Inserting The Battery; Loading The Nails Into The Magazine - FISCHER FGC 100 Manual Del Usuario

Ocultar thumbs Ver también para FGC 100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 114
6

Initial operation/setting

6.1 Loading the fuel cell

If you are using a new fuel cell, proceed as follows:
For the fuel cell with the Art.No. 553416
remove the safety cap and plug on the
metering valve.
Open the fuel cell compartment cover at the back of the tool. Insert the fuel cell into the
compartment in a way that the metering valve of the fuel cell is facing upwards and fitting into the
red adapter of the tool. Close the fuel cell compartment cover again.

6.2 Inserting the battery

Put the battery into the tool and make sure it is plugged in correct-
ly. Once the battery has been fitted, the battery-LED status lights
will light up showing the level of capacity of the battery or the
status of the tool.

6.3 Loading the nails into the magazine

Pull the push button back until it engages. Slide the nail strips into
the magazine in a way that the nails point towards the nose piece
of the tool. Release the push button by pressing the red button to
bring it back into its initial position.
Warning: Pay attention to keep your fingers clear off the pathway
of the push button when releasing from the lock position, other-
wise there is a risk of finger injury.
For the fuel cell with the Art.No. 538211
just plug on the metering valve.
EN
35

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

553411560038553585553586553587560091

Tabla de contenido