MO4LHCS8
C) MORSETTIERE - TERMINAL BLOCKS - BORNIERS - ANSCHLUSSKLEMMEN - TERMINALES
PIN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Refer to the manual for wiring details in the different operation mode
D) ESEMPI DI CONFIGURAZIONE - CONFIGURATION EXAMPLE - EXEMPLE DE CONFIGURATION - KONFIGURATIONSBEISPIEL - EJEMPLO DE CONFIGURACIÓN
Configuration with 2 dual channel outputs
(safety category SIL3/Pl e)
R
R S.p.A. Via Carcano 32, 10153 Torino Italia
EE
Tel. +39 0112482215 r.a. Fax +39 011859867
Sito web: www.reersafety.com - email: info@reer.it
SIGNAL
TYPE
24VDC
-
NODE_SEL0
Input
NODE_SEL1
Input
0VDC
-
REST_FBK1
Input
REST_FBK2
Input
REST_FBK3
Input
REST_FBK4
Input
OSSD1
Output
OSSD2
Output
OSSD3
Output
OSSD4
Output
-
-
24 VDC
-
-
-
-
-
OUT_STATUS1
Output
OUT_STATUS2
Output
OUT_STATUS3
Output
OUT_STATUS4
Output
OUT_STATUS5
Output
OUT_STATUS6
Output
OUT_STATUS7
Output
OUT_STATUS8
Output
NODE 0
NODE 1
NODE 2
NODE 3
DESCRIPTION
24VDC power supply
Node selection
(see following table)
0VDC power supply
Feedback/Restart 1
Feedback/Restart 2
Feedback/Restart 3
Feedback/Restart 4
Safety Output 1
Safety Output 2
Safety Output 3
Safety Output 4
-
24VDC power supply
-
-
SIL 1/PL c
SIL 1/PL c
SIL 1/PL c
SIL 1/PL c
SIL 1/PL c
SIL 1/PL c
SIL 1/PL c
SIL 1/PL c
CONFIGURATION NODE SEL
NODE_SEL0 (PIN 2)
0 (or not connected)
24VDC
0 (or not connected)
24VDC
Configuration with 4 single channel outputs
(safety category SIL3/Pl e)
QUICK INSTALLATION GUIDE
OPERATION
-
Input ("type B" according to EN 61131-2)
Input ("type B" according to EN 61131-2)
Input (according EN 61131-2)
Input (according EN 61131-2)
Input (according EN 61131-2)
Input (according EN 61131-2)
PNP active high
4 single channels (or 2 dual channels)
-
-
-
-
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
NODE_SEL1 (PIN 3)
0 (or not connected)
0 (or not connected)
24VDC
24VDC
2