6.2.3 Time schedule using the app
You can use the app to operate your pump on
the basis of a set work period. The pump then
receives a start or stop command for the set work
period via the network. Make sure that the pump
has a reliable network connection.
If the network connection is interrupted, the pump
will continue to run until it shuts down automati-
cally after a selected maximum running time.
6.2.4 SMART mode using the app
The pump's SMART mode enables automatic
watering. The use of SMART mode requires a
number of specifi c data.
For the pump to be able to determine how much
pumped medium is generally required within a
specifi c length of time you must fi rst run the pump
manually or by means of a time schedule on the
app. The general requirement is based on the
pump's fl ow rate.
Also needed are location-specifi c weather data
in order to determine the optimum watering time.
Proceed by entering the pump's location in the
app.
Once you have entered the data in the app,
SMART mode will show a progress indicator
telling you how much data still needs to be collec-
ted. As soon as the pump has collected enough
data, it will be ready to take over responsibility for
the watering itself.
6.3 Maximum running time
The maximum running time begins when the
pump receives a start command. The start com-
mand must be given manually or automatically
via the app. It is irrelevant whether the pump is
actually pumping or not. If the user does not issue
a stop command, the pump will switch off auto-
matically at the end of the set running time.
Important! – If the pump is started manually at
the pump by pressing the RESTART button (Fig.
5/Item A), the maximum running time setting will
not apply. As long as no stop command is issued,
the pump will run continuously.
Important! – The currently expired running time
will be reset with each start command via the app.
This can be done manually or automatically via
the app.
Anl_GE_AW_1144_SMART_SPK13.indb 22
Anl_GE_AW_1144_SMART_SPK13.indb 22
GB

6.4 Temperature monitoring

The pump monitors the temperature of the pum-
ped medium; this function is active independently
of the operating mode. If the temperature moni-
toring function triggers, the LED indicator (Fig. 5/
Item B) will blink red and the pump will switch off .
The temperature of the pumped medium was too
low or too high. Wait for the pumped medium to
reach the permissible operating temperature. You
can restart the pump by means of the RESTART
button (Fig. 5/Item A) or via the app.
The maximum temperature of the pumped medi-
um must not exceed +35 °C when the equipment
is operated permanently.
6.5 Error messages and warnings
Check the app at regular intervals for error mes-
sages and warnings. You will receive error mes-
sages, warnings and push notifi cations on your
smart-phone. This can be stopped by altering the
notifi cation settings in the app. Make sure that the
background data of the Einhell app are activated
on your smart-phone and that your smart-phone
has an active internet connection. You can locate
and eliminate the error (e.g. a leak in the intake
line) by consulting the operating manual and
the troubleshooting instructions. Then press the
RESTART button (Fig. 5/Item A) or acknowledge
the error message in the app in order to restart
the pump.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.