Water-i.d. ® water testing equipment User Manual Manuel d’utilisation Manual de usuario Gebrauchsanleitung Manuale dell’utente ® Electronic Pool Water Measurement...
DELIVERY CONTENT 1 x PoolLab 1.0 1 x Light shield 3 x AAA Batteries 1 x Crushing | Stirring Rods 1 x 10ml syringe 1 x User guide 20 x Phenol Red Photometer tablets 20 x DPD N° 1 Photometer tablets 10 x DPD N°...
SWITCH ON | ALLUMER | ENCENDER EINSCHALTEN | ACCENDERE 00:02 ZERO On/Off button can also be used to skip countdown during measurement (not recommended) Le bouton Marche/Arrêt peut être également utilisé pour ignorer le compte à rebours lors de la mesure (non recommandé) El botón de On/Off también se puede utilizar para cancelar la cuenta atrás durante la medición (no se recomienda) Die On/Off Taste kann auch zum Abbrechen des Countdowns...
ADVICES | CONSEILS | CONSEJOS HINWEISE | CONSIGLI Always use PHOTOMETER grade tablets! Never use RAPID grade tablets! Do not touch reagent tablets! Toujours utiliser des pastilles de qualité PHOTOMETRE! Ne jamais utiliser des pastilles de qualité "RAPID" ! Ne touchez pas les pastilles PHOTOMETER avec les mains! ¡Usar siempre tabletas...
Página 8
IMPORTANT | IMPORTANTE | WICHTIG Detergent waterproof (IP68 ) ZERO It is important to clean the device after each measurement to get rid of any reagent residues! Il est important de nettoyer le dispositif après chaque mesure pour éliminer les résidus de réactifs! Es importante limpiar el dispositivo después de cada medición para deshacerse de cualquier residuo de reactivo! Es ist wichtig, das Gerät nach jeder Messung zu reinigen, um...
Página 9
IMPORTANT | IMPORTANTE | WICHTIG Do not leave the device in the sun! Ne laissez pas l'appareil au soleil! ¡No deje el dispositivo al sol! Lassen Sie das Gerät nicht in der Sonne liegen! Non lasciare il dispositivo al sole! The PoolLab is also suitable for saltwater pools / salt electrolysis pools! Le PoolLab convient également aux piscines d'eau salée /...
NEW! Tablet Mode – Liquid Mode Tablettenmodus – Flüssigreagenz Modus Modo Tableta – Modo Reactivo Líquido Mode Comprimés – Mode Réactif Liquide Modalità Compressa – Modalità Reagente Liquido pH | fCl2 | tCl | cCl | Br | ClO | O Scan the QR-code to watch our intstruction video...
Página 11
Tablet Mode: Press And Hold ZERO + Power Button ZERO ZERO ZERO Liquid Mode: Press And Hold ZERO + Power Button ZERO ZERO ZERO...
Página 12
From firmware version 72 onwards, you have the option of measuring the following parameters with tablets as well as with liquid reagents: pH, chlorine, chlorine dioxide, ozone and bromine. You can choose between two measurement settings in the unit: Tablets and Liquid reagents. You can switch between the modes by pressing and releasing the ZERO &...
Página 13
A partir de la version 72 du firmware, vous avez la possibilité de mesurer les paramètres suivants aussi bien avec des pastilles qu'avec des réactifs liquides: pH, chlore, dioxyde de chlore, ozone et brome. Vous pouvez choisir entre deux réglages de mesure dans l'appareil: Comprimés et Réactifs liquides.
QUICK START GUIDE Kurzanleitung Guía De Inicio Rápido Guide De Démarrage Rapide Guida Rapida Scan the QR-code to watch our intstruction video...
Página 15
Hold & Press To Switch On 3 x AAA 00:02 ZERO START: Take 10 ml Water Sample 10 ml No Reagents! waterproof (IP68 ) ZERO Put On Lightshield ZERO ZERO ZERO ZERO...
Página 16
Remove Lightshield Reagent(s) For Your Test (Refer To Chapter In Manual) ZERO ZERO Put On Lightshield Use Force! ZERO ZERO Completely Residue Dissolved Shortcut Await For Your Countdown Test (Refer To Chapter In Manual) ZERO ZERO...
Página 17
Empty & Clean For Next Test: Take 10ml waterproof (IP68 ) ZERO 10 ml *If Device Was Not Switched *If Device Was Switched Off, Off, Start From Step 8 Start From Step 3 End Of Quick Start Guide | Ende der Kurzanleitung | Fin de la Guia Rapida Fin du guide de démarrage rapide | Fine della guida rapida...
ZERO waterproof (IP68 ) ZERO Take 10 ml Water Sample 10 ml No Reagents! waterproof (IP68 ) ZERO ZERO ZERO ZERO...
Página 19
Only 1 time per test batch Une seule fois par lot de test Sólo una vez por lote de prueba Nur 1 x pro Testreihe Solo una volta per test in batch The "ZERO" step (page 18) is only necessary once after switching on. Make sure that the water to be measured does not (!) contain any tablet/reagent in the cuvette and that the light protection cover is in place.
Liquid Mode: Tablet Mode: 6.50 – 8.40 pH 6.50 – 8.40 pH Phenol Red Liquid* Phenol Red Photometer *not part of standard equipment waterproof (IP68 ) ZERO take 10 ml water sample waterproof (IP68 ) 10 ml ZERO...
Página 21
Tablet Or Liquid? (p. 10) Phenol Red Photometer ZERO! (p.18) 6 x Phenol ZERO ZERO Use Force! Completely Dissolved ZERO ZERO Residue...
Página 22
ZERO The Total Alkalinity value has to be minimum 50 mg/l to obtain a correct pH value. La valeur totale de l'alcalinité doit être au minimum de 50 mg/l pour obtenir une valeur de pH correcte. El valor de alcalinidad debe ser superior a 50 mg/l para obtener un pH correcto.
Página 25
Tablet Or Liquid? (p. 10) DPD N°1 Photometer 3 x DPD 1A + ZERO! (p.18) 3 x DPD 1B ZERO ZERO Use Force! Completely Dissolved ZERO ZERO Residue...
Página 26
Tablet Or Liquid? (p. 10) DPD N°3 Photometer 3 x DPD 3C ZERO ZERO ppm = mg/l Use force! Completely Dissolved ZERO ZERO Residue...
Página 27
ZERO Total Chlorine is measured directly after free Chlorine without emptying the cuvette. The DPD 3 tablet is added to the sample water which already contains the DPD 1 tablet (dissolved). Combined Chlorine is calculated as Total Chlorine minus free Chlorine. The free chlorine measurement must be taken within 1 minute after dissolving the tablet.
Página 28
El cloro total se mide directamente después de cloro libre, sin necesidad de vaciar la cubeta. La tableta DPD 3 se añade a la cubeta en la que la tableta DPD 1 ya está disuelta. El cloro combinado se calcula a partir de cloro total menos cloro libre.
Cyanuric Acid Acide Nurique Ácido Cianúrico Cyanursäure Acido Cianurico 0 – 160 ppm (mg/l) CYA–Test Photometer waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 31
1 x CYA–Test Use Force! Photometer Completely Dissolved ZERO ZERO Residue ZERO ZERO...
Active Oxygen Oxygène actif Oxígeno activo Aktivsauerstoff Ossigeno Attivo (MPS) 0.0 – 30.0 ppm (mg/l) DPD N°4 Photometer* 10.0 30.0 *not part of standard equipment waterproof (IP68 ) ZERO take 10 ml water sample waterproof (IP68 ) 10 ml ZERO...
Página 35
1 x DPD N°4 Use Force! Photometer* ZERO! (p.18) Completely Dissolved ZERO ZERO ZERO Residue ZERO ZERO...
Página 37
Only if your water sample does contain Chlorine next to Chlorine Dioxide (both disinfectants used), the following procedure "A" needs to be followed and Glycine reagent needs to be used. Otherwise (only Chlorine Dioxide present), please follow procedure "B". Seulement si votre échantillon d'eau contient du chlore avec du dioxyde de chlore (les deux désinfectants utilisés), la procédure suivante «A»...
Página 38
With Chlorine | Mit Chlor Con Cloro | Avec Du Chlore | Con il Cloro Glycine* Use Force! Completely Dissolved ZERO ZERO Residue Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! 3 x DPD 1A + 3 x DPD 1B Completely Dissolved ZERO...
Página 39
Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! 3 x DPD 1A + 3 x DPD 1B Completely Dissolved ZERO ZERO Residue 8 /6 ZERO ZERO...
Página 41
Only if your water sample does contain Chlorine next to Bromine (both disinfectants used), the following procedure "A" needs to be followed and Glycine reagent needs to be used. Otherwise (only Bromine present), please follow procedure "B" Seulement si votre échantillon d'eau contient du chlore avec du Brome (les deux désinfectants utilisés), la procédure suivante «A»...
Página 42
With Chlorine | Mit Chlor | Con Cloro Avec Du Chlore | Con il Cloro Glycine* Use Force! Completely dissolved ZERO ZERO Residue Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! 3 x DPD 1A + 3 x DPD 1B Completely dissolved ZERO...
Página 43
Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 Photometer 3 x DPD 1A + Use Force! 3 x DPD 1B Completely Dissolved ZERO ZERO Residue 8 /6 ZERO ZERO...
Página 45
Only if your water sample does contain Ozone next to Chlorine (both disinfectants used), the following procedure "B" needs to be followed and Glycine reagent needs to be used. Otherwise (only Ozone present), please follow procedure "A". Seulement si votre échantillon d'eau contient du chlore avec de l‘...
Página 46
Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer 3 x DPD 1A + 3 x DPD 1B + 3 x DPD 3C Completely Dissolved ZERO...
Página 47
With Chlorine | Mit Chlor Con Cloro | Avec Du Chlore | Con il Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer 3 x DPD 1A + 3 x DPD 1B + Completely 3 x DPD 3C Dissolved ZERO ZERO...
Página 48
With Chlorine | Avec Du Chlore Con Cloro | Mit Chlor | Con il Cloro 0 ml ZERO 10 ml waterproof (IP68 ) ZERO Glycine* Use Force! Completely Dissolved ZERO ZERO Residue...
Página 49
With Chlorine | Avec Du Chlore Con Cloro | Mit Chlor | Con il Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer 3 x DPD 1A + 3 x DPD 1B + Completely 3 x DPD 3C Dissolved ZERO ZERO...
Página 50
Hydrogen Peroxide Peroxyde d'Hydrogène Peróxido de Hidrógeno Wasserstoffperoxid Perossido di Idrogeno (LR) 0.00 – 2.90 ppm (mg/l) Hydr. Peroxide LR Photometer* 0.00 1.45 2.90 *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 )
Página 51
1 x Hydr. Peroxide Use force! Photometer* completely dissolved ZERO ZERO residue ZERO ZERO...
Página 52
Hydrogen Peroxide Peroxyde d'Hydrogène Peróxido de Hidrógeno Wasserstoffperoxid Perossido di Idrogeno (HR) 0 – 200 ppm (mg/l) Hydr. Peroxide HR Photometer | Acidifying PT *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 )
Página 53
1 x Acidifying Use Force! ZERO ZERO Completely Dissolved Residue 1 x Hydr. Peroxide Photometer* Use Force! ZERO ZERO Completely Dissolved Residue ZERO ZERO...
Total Hardness Dureté Totale Dureza Total Gesamthärte Durezza Totale 0 – 500 ppm (mg/l) CaCO POL20TH1 | POL10TH2 *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 55
POL20TH1* POL10TH2* *shake before use! 10 x ZERO ZERO ZERO ZERO...
Calcium Hardness Dureté Calcique Dureza de Calcio Kalziumhärte Durezza del Calcio 0 – 500 ppm (mg/l) CaCO POL20CaH1 | POL20CaH2 *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 57
POL20CaH1* POL20CaH2* *shake before use! 10 x 10 x ZERO ZERO ZERO ZERO...
Urea Urée Harnstoff 0.1 – 2.5 ppm (mg/l) Dechlor | PL Urea 1 | PL Urea 2 Ammonia N°1 | Ammonia N° 2 *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml...
Página 61
1 x Dechlor ZERO ZERO Use Force! ZERO ZERO Completely Dissolved Residue PL Urea *Shake Before Use! ZERO ZERO...
Página 62
PL Urea *Shake Before Use! ZERO ZERO ZERO ZERO...
Página 63
4 14 Ammonia N° 1 ZERO ZERO Ammonia N° 2 ZERO ZERO...
Página 64
ZERO ZERO If the sample contains free chlorine, a „Dechlor“ tablet has to be added to the vial, before adding PL Urea 1 and PL Urea 2. Ammonia N° 1 only dissolves entirely after Ammonia N° 2 was added. Ammonia and chloramines will be detected together.
Página 65
Si la muestra contiene cloro libre, hay que añadir una pastilla de "Dechlor" al vial, antes de añadir PL Urea 1 y PL Urea 2. Ammonia N°1 no se disuelve por completo hasta que agregue Ammonia Nº 2. El amoníaco y cloraminas se detectan juntos. Por consiguiente, el resultado mostrado es la suma de los dos.
PHMB 5 – 60 ppm (mg/l) PHMB Photometer* *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
Página 67
1 x PHMB Photometer Use Force! Completely Dissolved ZERO ZERO Residue ZERO ZERO...
Página 68
It is imperative that you clean the objects used for the measurement and come into contact with the sample water containing the reagent (cuvette, lid, stirring rod) thoroughly with a brush, water and then with distilled water, otherwise the measuring equipment may turn blue over time. Alkalinity values (M) <>...
Página 69
Reinigen Sie unbedingt die für die Messung verwendeten und mit dem mit Reagenz versetzten Messwasser in Berührung gekommenen Gegenstände (Küvette, Deckel, Rührstab) gründlich mit einer Bürste, Wasser und anschließend mit destilliertem Wasser, da sich ansonsten das Messbesteck mit der Zeit blau verfärben kann. Alkalinitätswerte (M) <>120 mg/l und Calzium-Härte-Werte <>200 mg/l können zu Messwertabweichungen führen.
OR-UR (DILUTION) | OR-UR (VERDÜNNUNG) OR-UR (DILUCIÓN) | OR-UR (DILUZIONE) OR = Overrange / UR = underrange. Test result is outside the range of the method. OR results can be brought into measurement range by dilution. Use syringe to take only 5ml (or 1ml) sample water plus 5ml (9ml) distilled water.
TROUBLESHOOT | DÉPANNAGE | SOLUC. PROBLEMAS FEHLERBEHEBUNG | RISOLUZIONE DIE PROBLEMI 1) 01.01.1970: The date on the PoolLab is set to 01.01.1970 when delivered, after each battery change and after each update. Please reconnect to the LabCOM app so that the smartphone date is adopted again.
Página 73
4) Aplastar las pastillas enérgicamente con la varilla agitadora. La cubeta no se rompe 5) El cloro total puede mostrarse más bajo que el cloro libre dentro de las tolerancias indicadas en este manual. 6) Humedad en la pantalla: Puede ocurrir si la humedad residual en la carcasa se condensa debido al agua fría durante la inmersión.
TECHNICAL DATA | DONNÉES TECHNIQUES DATOS TÉCNICOS | TECHNISCHE DATEN DATI TECNICI www.poollab.org MSDS msds.water-id.com Cloud labcom.cloud 530 nm / 570 nm / 620 nm LED: 3 x AAA (1.5 V, LR03) 300 sec. ï 5 - 45°C IP 68 (1 h / 1.2 m) Developed in Germany Produced in PRC...
DISPOSAL Device According to EC Directive 2002/ 96/EC, electronic devices must not be disposed of in normal domestic waste. The manu-facturer of this device, Water-i.d.® GmbH, Daimlerstr. 20, D-76344 Eggenstein will dispose of your PoolLab Photometer free of charge (not including costs of sending the device to us).
Página 84
UKCA Complaince Statement UK Conformity Assessed We, Water-i.d. GmbH Germany, hereby certify our responsibility, that the following product: PrimeLab 2.0 Photometer, is tested to and conforms with the essential test suites included in the following standards, which are in force within the UK: Standards Legislation Number Regulations 2016 (S.I.
Página 85
FCC PART 15 COMPLIANCE STATEMENT IC LICENCE-EXEMPT RSS COMPLIANCE STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Página 86
Cet émetteur ne doit pas être co-situé ou fonctionner conjointement avec une autre antenne ou un autre émetteur. Changes or modifications not expressly approved by Water-i.d. GmbH could void the user‘s authority to operate the equipment. FCC ID: 2ALRR-POOLLAB10 22610- POOLLAB10 Model: POOL LAB 1.0...
CERTIFICATE | CERTIFICAT | CERTIFICADO ZERTIFIKAT | CERTIFICATO CERTIFICATE OF COMPLIANCE We hereby certify that the device PoolLab 1.0® With it‘s serial number as stated below, has passed intensive visual and technical checks as part of our QM documentation. We confirm the device got factory-calibrated. Water-i.d.®...