IV. Installation
1. Turn off the cold water supply.
2. Connect the cold water hose with the cold water inlet of the scale inhibitor,
and tighten the nut with a wrench. Please don't miss the gasket.
If the water hose is 3/4", attach the 3/4" adaptor to the cold water inlet
before connecting the hose.
3. Connect the cold water hose with the �ltered water outlet of the scale
inhibitor. Please don't miss the gasket. If the water hose is 3/4", attach
the 3/4" adaptor to the �ltered water outlet before connecting the hose.
4. Turn on the cold water supply. Wipe the connections with a tissue to see
if there is leakage. If the tissue stays dry, it means it is installed properly.
3
V. Re�ll antiscalant
1. Turn off the cold water supply.
2. Turn the bottom cap clockwise to remove it.
3. Take out the �lter cartridge, remove the cap, and take out the emptied
fabric bag.
4. Rinse the stainless steel mesh of the �lter cartridge with tap water, �ll the
cartridge with a new bag of the antiscalant, and put the cap back on the
�lter cartridge.
5. Put the �lter cartridge back in the scale inhibitor, and twist the bottom
cap anticlockwise until it's tightened.
1
2
12