able to stand the pump on a solid platform at
the bottom to keep it upright, if practical to do
so. Ensure there are no obstructions around the
inlet openings around the base of the pump.
The inlet openings must be clear of mud or
sludge at the bottom of a pool.
3. Connect the mains plug.
4. When the pump is lowered into the water and
the power is switched on, it will start to operate
as soon the water level exceeds the top contact
point of the sensor switch (7).
5. The pump switches off as soon the water level
is below the lower contact point of the sensor
switch (7) due to the falling water level.
6. After use, remove the mains plug from the
mains.
7. Lift the pump back out of the water.
Continuous operation (Fig. D, F)
1. Slide the sensor switch (7) into the sensor
switch holder (9).
2. Lower the pump into water. It would be advis-
able to stand the pump on a solid platform at
the bottom to keep it upright, if practical to do
so. Ensure there are no obstructions around the
inlet openings around the base of the pump.
The inlet openings must be clear of mud or
sludge at the bottom of a pool.
3. Connect the mains plug.
4. On continuous mode, the pump will always run.
Do not leave the pump unattended.
5. After use, remove the mains plug from the
mains.
6. Lift the pump back out of the water.
Finish operation
After use allow the pump to run using clean water
for 2 - 3 minutes in order to remove residues and
particles that may have accumulated in the pump
and outlet hose.
5. MAINTENANCE
Before cleaning and maintenance, always
switch off the machine and remove the
mains plug from the mains.
During maintenance or cleaning never rest
the appliance of the on the turbine
(impeller).
WWW.VONROC.COM
Clean the machine casings regularly with a soft
cloth, preferably after each use. Remove very per-
sistent dirt using a soft cloth moistened with soap-
suds. Do not use any solvents such as gasoline,
alcohol, ammonia, etc. Chemicals such as these
will damage the synthetic components.
If the appliance appears to be blocked, switch off
the power at the mains, remove the plug from the
socket and check the appliance for blockages (see
'Blockages').
Clean the sensor switch
Clean the sensor switch (7) at regular intervals, and
check it for damage. Otherwise, its function can be
impaired.
Blockages
If you suspect the pump has become blocked,
switch off the power at the mains socket remove
the plug and examine the turbine. The turbine can
be accessed by removing the securing screws in
the base and/or sub base. Alternately try reaching
the suspected blockage through the outlet (4) in
the side of the pump.
Always flush through with clean water after
every use.
STORAGE AND FROST POTECTION
The submersible pump and accessories that are
not completely drained can be destroyed by frost.
Completely drain the submersible pump and acces-
sories and protect them against frost.
Keep this appliance in well-ventilated dry premises
with temperature not going below +5°C.
When not in use, keep this appliance stored in a
safe place out of reach of children.
TROUBLE SHOOTING GUIDE
Problem
Cause
Pump does not
No mains supply
start
Sensor switch is
dirty
Not the right
operating mode
EN
Remedy
Check mains supply
Clean the sensor
switch
Check the operation
mode. (see 'OPERA-
TION')
7