Kenmore 148.16154210 Guía Para Su Uso Y Cuidado página 27

Ocultar thumbs Ver también para 148.16154210:
Tabla de contenido

Publicidad

Problem
Possible Cause
Low heat with the
knob in "HI"
position
Low heat, natural
gas
Low heat,
LP gas
Sudden drop in
gas flow or low
flame
All manuals and user guides at all-guides.com
1. Low heat is found in natural
gas models.
2. Ports are blocked.
3. LP tank has run out.
Gas pressure is significantly
affected by gas line and
length of gas line from house
gas line.
The propane regulator
assembly incorporates an
excess flow device designed
to supply the grill with
sufficient gas flow. Rapid
changes in pressure can
trigger the excess flow device,
providing a low flame and low
temperature.
1. Out of gas.
2. Excess flow valve tripped.
3. Vapor lock at coupling
nut/LP cylinder
connection.
Corrective Action
1. This model is set for 7 in. natural gas
usage. Please check your natural gas
supply system to have correct gas
pressure.
Regulator is not needed for NG
model.
Check the orifice if you installed NG
nozzles.
2. Clear ports of any obstructions.
3. Refill the LP tank.
Check your gas line and make
corrections by following the chart below.
From House to Grill
Distance
Up to 25 ft. 3/8 in. diameter
26 -50 ft.
51 -100 ft.
Please follow these instructions:
1. Make sure all burners are "OFF".
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time
following the lighting instructions
listed on the door liner
1. Check for gas in LP cylinder.
2. Turn off knobs, wait 30 seconds and
light grill. If flames are still low, turn
off knobs and LP cylinder valve.
Disconnect regulator. Reconnect
regulator and leak test. Turn on LP
cylinder valve, wait 30 seconds and
then light grill.
3. Turn off knobs and LP cylinder valve.
Disconnect coupling nut from
cylinder. Reconnect and retry.
27
Tubing Size
1/2 in. diameter
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido