Electrical connection

An omnipolar disconnector switch must be
installed upstream of the cabinet. This must
have:
• Minimum distance of the contacts of 3
mm.
• Adequate breaking power
The disconnector switch must be placed in a
position that makes it easy to operate in
emergency situations (maximum distance of 3
m).
Before connecting the cabinet, ensure that the
supply voltage corresponds to the rating plate
data of the cabinet. To guarantee smooth
operation, the maximum voltage variation must
be between +/- 6% of the nominal value.
9.6

Technical features

The identification plate shows the characteristic
technical data of the cabinet. Its position and
the type of data are shown in "Technical
features" ("Fig. 23").
Wiring diagrams, control instrument calibration
lists, installation instructions and copy of the
Declaration of Conformity are available on the
website https://documents.eptarefrigeration.
com.
The sound pressure level generated by the
operation of the cabinet is lower than 70 dB(A).
The cabinet does not cause harmful vibrations.
9.7

Loading the product

Energise the cabinet to start its cooling cycle,
by acting on the general disconnector switch
mounted on the wall. After about 2 hours it is
possible to load the cabinet.
The cabinet is suitable to maintain the
temperature of the goods and not lower it; the
foods, therefore, must be introduced inside it
only if already cooled to the respective
temperatures of preservation. Products which
have been heated must never be introduced
into the cabinet.
N°DOC. UM000442 REV. "E" - 16/03/22
SILK - SILK SV
Epta Spa - Via Mecenate, 86 - 20138 Milano (MI) ITALIA
Tel. 02/55403211 Telefax 02/55401023
In the presence of glass fronts on the cabinet, it
is recommended to load the goods when there
is no customer in the sales area.
In loading the goods, ensure that:
• The load is homogeneous in terms of
dimension and quality of the products
• The goods do not obstruct the correct flow
of refrigerated air ("Fig. 24")
• The goods do not exceed the load line
Uniformly distributed maximum permissible
load:
• On the bottom level: 90 kg/m
• On the shelves: 225 kg/m
9.8

Use of cabinet

Lighting
The lighting of the counter is controlled by a
switch placed under the decorative panel ("Fig.
27").
Temperature display
On the counter, at the level of the air intake
grille, there is a display for viewing the
temperature ("Fig. 26").
Inclination of the display shelves and the
bottom shelf
By varying the hooking position of the shelves
and bottom surface with the rear rear slots of
the counter, different inclinations are allowed
("Fig. 28").
The inclination of the shelves and bottom
surface inside the counter vary according to the
version and depth (chart "Chart III").