As option there are this mounting accessories:
Wall mount bracket for adjustable arm Luminaire
T-slot bracket for adjustable arm Luminaire
Screw-on base, plastics incl. screws for adjustable arm Luminaire
Fastening plate, aluminium
Universal table clamp (spare part)

5 | Connection

Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK.
Operate the luminare with the supplied power supply unit (PSU) only! No direct connection to 230V AC or other
electric power supplies!
PIN assignment of the M12 connector is as follows:
PIN assignment
PIN 1
= 24V DC
PIN 2
= not used
PIN 3
= GND
PIN 4
= 24V DC
PIN 5
= not used
10 | BA UNILED II . BA 05/2022
When mounting the luminaire, make sure that the luminaire is fastened securely and
stably. If the luminaire falls down, its weight poses a risk of injury!
Schematic drawing of M12 plug
Possible variants of the M12 connector
PIN 3 = 0V DC. 24V DC for supply can be connected to PIN1 or PIN 4. It is not necessary to
assign both PINs (PIN 1 and PIN 4) at once!
To turn on the luminaire, activate the switch on the side of the luminaire body and set it to [ I ].
Dimable version: Hold on the push button for setting of the light intensity. Save light
intensity (MEMORY FUNCTION): Press push button shortly twice; the luminaire is
blinking for confirmation.