EAS ELECTRIC EINSOLAR5V Manual De Usuario E Instalacion página 29

Ocultar thumbs Ver también para EINSOLAR5V:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

inverter
Utility grid
detected grid
9
disconnected
voltage failed
grid voltage
exceeds the Safety
Grid voltage
regulations
exceeds the
10
permissible
range
Grid
grid frequency
frequency
11
exceeds the safety
exceeds the
permissible
regulations
range
26
1. If it happens occasionally, it belongs
to the short-time abnormality of the
power grid, the inverter will return to
normal operation after detecting that
the power grid is normal, and there is
no need to deal with it.
2. If it cannot be recovered for a long
time, please confirm:
 whether the AC circuit breaker is
disconnected
 whether the AC terminal or fuse is in
good contact
 whether the power supply line is normal
If this fault is still being shown, contact
the service.
1. If it happens occasionally, it belongs to
the short-time abnormality of the
power grid, the inverter will return to
normal operation after detecting the
normal power grid, and there is no
need to deal with it.
2. In case of frequent occurrence but
automatic recovery, please confirm if
the grid voltage is outside the
permissible range due to local grid
conditions, try to modify the values of
the monitored operational limits after
informing the electric utility company
first.
3. If it cannot be recovered for a long
time, please confirm:
· whether the AC circuit breaker is
disconnected
· whether the AC terminal is in good
connection
·
whether the power supply line is normal
·
whether the AC cable wiring (such as wire
length and wire diameter) complies with
the user manual guidance
·
whether the safety regulation settings are
normal
1. If it happens occasionally, it
belongs to the short-time
abnormality of the power grid, the inverter
will return to normal operation after
detecting the normal power grid, and
there is no need to deal with it.
2. In case of frequent occurrence but
automatic recovery, please confirm if the
grid voltage is outside the permissible
range due to local grid conditions, try to
modify the values of the monitored
operational limits after informing the
electric utility company first.
DC
component of
the electricity
12
exceeds the
permissible
range
EEPROM
Error, e.g.
13
transition
disturbance
Internal
communica-
14
tion fault
Bus-voltage
15
too high
Bus-voltage
16
too low
17
DRM S9 Error
V.2
3. If it cannot be recovered for a long time,
please confirm:
· whether the AC circuit breaker is disconnected
· whether the AC terminal is in good connection
· whether the power supply line is normal
· whether the safety regulation settings are
normal
the current
Disconnect the inverter from the utility
exceeds 1A in static
grid and the PV array, and reconnect it
state and 4A in
after LED turns off. If this fault is still being
dynamic state
displayed, please contact the service.
Disconnect the inverter from the
utility grid and the PV array, and
Micro CPU read
reconnect it after LED turns off. If this fault
EEPROM failed
is still being displayed, please contact the
service.
Master CPU
Disconnect the inverter from the utility
communicate
grid and the PV array, and reconnect it
with slave CPU
after LED turns off. If this fault is still being
abnormal
displayed, please contact the service.
Check the open-circuit voltages of the
strings and make sure it is below the
Bus-voltage is
maximum DC input voltage of the
greater than 600V
inverter. If the input voltage lies within the
permissible range while the fault occurs,
please contact the service.
Check the open circuit voltage of the
Bus-voltage is 20V
strings and make sure it is below the
lower than
maximum DC input voltage of the inverter.
standard bus
If the input voltage lies within the
voltage
permissible range while the fault occurs,
please contact the service.
Check the connection of DRM device. If
the DRM device is connected normally
DRM switch S9
while this fault occurs, please contact
fault
the service.
27
V.2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Einsolar6.5v

Tabla de contenido