Palmer PTRAVE Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
USER MANUAL
TECHNICAL DATA
GENERAL
Product number
Product type
No. of channels
Type
Transformer isolated
No. of inputs
Input type
Input connections
No. of outputs
Output type
Output connections
Ground/lift switch
Additional functions
Housing
Dimensions (H/W/D)
Weight
Ambient temperature for operation
Relative air humidity
Included accessories
AUDIO
Max. input level (<1% THD, 20 Hz)
Max. input level (< 1% THD, 1 kHz)
Frequency response (±1 dB, relative 1 kHz)
Input impedance (1 kHz, setting: max. level, -10 dBV)
Output impedance (1 kHz, setting: max. level, -10 dBV)
THD (30 Hz, +4 dBu, unity, unweighted)
THD (1 kHz, +4 dBu, unity, unweighted)
IMD (SMPTE) (60 Hz/7 kHz, 4:1, +4 dBu)
Transformer ratio
All measurements were performed with a generator with 100 Ω output impedance and 100 kΩ balanced load.
EN
PTRAVE
DI box
1
passive
yes
1
balanced
XLR
1
unbalanced
6.3 mm jack
yes
Input level switch, output level potentiometer
Aluminium continuous casting
140 x 50 x 68 mm
0.395 kg
-20°C...70°C
<80%, non-condensing
Rubber feet
+19 dBu
+32 dBu
10 Hz to 20 kHz
5 kΩ
4.2 kΩ
< 0.08%
< 0.003%
< 0.004%
1:3
14

Publicidad

Tabla de contenido
loading