IMPORTANT: the complete length of cable used to interconnect the devices in a line must not exceed 100
meters. To prevent line interference, it is recommended that an electric terminator consisting of a 120 Ω
resistor be placed at the last element in the chain between pins 2 and 3 of the XLR DMX OUT connector of
the last element.
- Connect all the elements to the power supply and turn them on to start using them.
MASTER SLAVE CONTROL
The master-slave function allows several lights to operate in synchronization (same color and same move-
ments) without the need of a DMX controller.
- Cascade the BAR-73L you want to use.
- Select the slave mode (A001) on every light except the one you want to be the master ("MASTER"). These
lights are referred to as slave lights (SLAVE.
- At the MASTER light select any of the operating modes other than DMX control.
SECURITY RECOMMENDATIONS
- Do not under any circumstances access the internal parts of the device.
- Make sure that the device is at least 50 cm away from flammable substances or elements.
- Looking at the rays from any distance less that 15 cm can cause serious damage to the eyes, as can
direct exposure to radiation for more than 10 seconds.
- Continuously switching the unit on and off will result in a decreased life span of the unit.
- These devices should only be used in areas that are refrigerated and under cover.
- Do not move or handle the appliance while it is connected to the mains and in operation.
- Do not modify the lighting elements of the device without technical supervision or with any materials that
are not approved by the supplier.
TECHNICAL SPECIFICATIONS
LED
DMX CHANNELS
INPUTS
OUTPUTS
CONTROLS
POWER SUPPLY
DIMENSIONS
ACCESSORIES
BAR-73L
24 x 3 W, LED RGB (3 in 1)
2, 3, 4, 6, 7, 12 or 24 channels
DMX IN, 3 pin XLR
DMX OUT, 3 pin XLR
POWER OUT, 4 A maximum
Configuration screen
100-240 V AC, 80 W
1,020 x 65 x 65 mm depth
Adjustable mounting bracket
- 7 -
EN