3: Warranty; 4: Installing Controller; Mounting Controller; Installing The Temperature Sensor In Follow Mode - Eye Hortilux GRC-LED Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. WARRANTY
2-year warranty from the date of purchase.
EYE Lighting International of North America ("EYE Lighting") warrants the mechanical and electronic
components of the EYE HORTILUX controllers to be free from defects in material and workmanship
provided that such controllers are operated under normal operating conditions for a period of (2) years
from the original date of purchase. If the product shows any defects within this period and that defect
is not due to user error or improper use, EYE Lighting shall, at its discretion, either replace or repair the
system using suitable new or reconditioned parts.
All warranty claims must be directed to the retail store where the EYE HORTILUX product was purchased.
LIMITATION OF LIABILITY
The warranty and remedies set forth herein are in lieu of any and all other warranties express or
implied, including any warranty of merchantability or fitness for a particular purpose . In the event
of a breach of warranty, EYE Lighting International of North America ("EYE Lighting") shall, in its
sole discretion, repair or replace the non-conforming product or refund the purchase price within
a reasonable time . EYE Lighting shall not be obligated or liable for any indirect, consequential, or
incidental damages for breach of this or any other warranty, express or implied, or for any claim
based on contract, tort, or any other legal theory . In no event shall EYE Lighting's liability exceed the
purchase price of the product .
4. INSTALLING THE CONTROLLER
4.1 Mounting the Controller
WARNING! The area in which the product is placed must comply with the conditions specified in
section 1.2.
CAUTION! Only mount the product on a sturdy, solid surface.
1. Determine the optimal location for the controller.
2. Carefully remove the mounting plate from the controller.
3. Hang the mounting plate against the desired surface using #6 x 1" flat-head screws.
4. Secure the controller into the mounting clamp. Controller should click into place when properly
secured.

4.2 Installing the Temperature Sensor in Follow Mode

1. Place the provided temperature sensor as close as
possible to the sensor of the existing climate control
system, so both sensors will measure the same
temperature (Figure 6A)
2. Ensure the sensor is covered from the light, as this
will disrupt temperature measurements. Use a hood if
necessary (Figure 6B).
3. Insert the plug of the temperature sensor into the T1 port
(Figure 6C)
4. The temperature measured by the sensor will be
displayed on the controller display.
Notes: The displayed temperature may take some time to level
out. | If the length of the sensor cable is insufficient to reach the
controller, try to relocate the controller. If this is not possible,
the sensor cable may be lengthened an extra 5 meters by using
a standard 3.5 mm jack extension cable. | If the T: or RH: read
"N/A", the plug of the sensor is not (fully) plugged in. Plug the
sensor in completely.
6
Visit eyehortilux.com for the latest installation instructions.