4.4 Recommended Tools

1.Secure the Charging Station mounting bracket to the wall using four 6*50 expansion screws and bracket holes.
Power cables cab be connected from the upside as in figure 4-1
2.See Figure 4-1. Screw two M6*10 hexagon socket cap screws to the back of the box, and mounting to the bracket.
3.Screw one M6*10 cross round head with washer screw from box inside securing to the bracket.
Note:
The Charging Station must be mounted at a sufficient height from grade such that the height of the plug dock
is located between 24–48 in. (0.6–1.2 m) from grade per NEC Article 625.
4.5 Installing the Power wires to Charging Station
1.See Figure 4-2.
It is the instruction for 1-Phase 7KW power wires connection.
Figure 4-1. Mounting brackets
12V
TYPE B
AC/DC
N
L
Figure 4-2. Power wires connection