4. Feed AC supply leads through top (or side) hole on
the housing and the crossbar and make the proper
supply lead connections. If using 120VAC, connect
the black and white leads to the building utility. If
using 277VAC, connect the orange and white leads
to the building utility. Cap-off unused wire. If the unit
is self-powered, be sure to snap battery connector
together. During installation, use the enclosed
"holding wire" for assistance. (See Figures 6-7)
5. Push excess wire into junction box and align holes
in canopy with those in crossbar. Using screws
supplied, tighten canopy to crossbar so that canopy
is securely fastened and tight against ceiling or wall.
6. Snap EXIT panel into the housing, bottom first and
then top.
PAGE 3 OF 9
INSTALLATION CONTINUED
Figure 7
1-800-295-5510
uline.com
Figure 6
Junction Box
Wire Nuts
Crossbar
Canopy Screws
Crossbar Screws
Housing
EXIT Panel
Ceiling Mounted Setup
Supply
Housing
Leads
Crossbar
Screws
EXIT Panel
Side Mounted Setup
Canopy
Supply
Leads
Canopy
Screws
Wire Nuts
Crossbar
Junction Box
Canopy
0222 IH-9980