8. General technical indicators

Environmental conditions of use:
IEC/EN 61010-1 600V CAT III, pollution class 2
Altitude: < 2000 m
Working environment temperature and humidity: 0~40℃
(<80% RH, no need to consider when <10℃)
Storage environment temperature and humidity: -10~60℃
(<70% RH, remove the battery)
Temperature coefficient: 0.1 - accuracy/°C
Maximum allowable voltage between measurement terminal
and ground: 600v DC or AC RMS
Fuse protection: Fuse FF250mA/250v
Sampling rate: about 3 times/sec.
Display: 3 1/2-digit LCD
Outrange indication: "OL" displaying on the LCD screen.
Battery low voltage: When the battery voltage is lower than
the normal operating voltage "
" sign will be shown on
the display.
Input polarity indication: automatically display " - " sign
Power supply: 2x1.5V AAA battery
Dimension: 225x38x26mm