All manuals and user guides at all-guides.com
2. Follow the instructions for the device that must be combined to generate the required
command message.
The LED will go OFF to indicated that the RF message has been learnt.
3. After 5 seconds the LED will come back ON and it is possible to memorise another RF
message, repeating the procedure 2 above. If the LED flashes (red), this means that
the memory is full (4 transmitters memorised on each channel) and it is therefore
necessary to use another channel.
4. If necessary, turn the rotating switch to the next position (2, 3... 8) and repeat
procedure 2 to memorise the other transmitters.
WARNING: Do not turn the rotating switch to position 9.
5. After memorising all the required transmitters, turn the rotating switch to position 0
for standard functions In this position the receiver LED flashes green briefly each time
it receives a message from any of the learnt RF devices.
To cancel the combinations memorised on the various RF channels, turn the rotating
switch to position 9: the front LED will flash for 10 seconds (yellow) and then remain ON
(yellow) to indicate that all the channel combinations have been cancelled.
To interrupt the cancellation procedure, turn the selector switch to another position before
the LED stops flashing.
WARNING: It is not possible to perform selective cancellations: the
cancellation operation requires new learning of all the required RF
transmitters.
Insert the device into a Chorus support, making sure the Easy EIB channel localisation
button is on the left.
Complete the installation with other Chorus devices or covers and fix it to the relative
container (flush-mounted box, wall-mounted box etc).
Apply the finish plate.
INSTALLATION
Cancelling learnt RF channels
Completing installation
26