12
UK
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
1
2
3
1 230 Vac input (Phase).
2 230 Vac input (Neutral).
3 Motor opening output (Open).
4 Common motor output.
5 Motor closing output (Close).
6 Command output for anti-tampering device
("MAXI control unit") (sold separately).
7 230 Vac courtesy light / external flashing light (Phase).
8 230 Vac courtesy light / external flashing light (Neutral).
OPERATION
STEP-BY-STEP OPERATION: (2 buttons remote control):
The first impulse by remote control starts the operation of the motor in the direction corresponding to the button
pushed until the motor time expiring or limit switch reaching.
If you give a second impulse with any button before the motor time expiring or limit switch reaching, the motor stops.
A command more makes the motion starts again in the direction corresponding to the button pushed..
STEP-BY-STEP OPERATION (1 button remote control or low tension button):
The first impulse (by remote control or low tension button) commands the opening until the motor time expiring or limit
switch reaching.
The second impulse commands the rolling shutter closing.
If you give an impulse before the motor time expiring, the motion stops; a command more makes the motion starts
again in the opposite direction.
AUTOMATIC CLOSING:
If the automatic closing function is enabled, the control unit automatically closes the rolling shutter again (when it is
on the opening limit switch), without sending any additional command.
SAFETY DEVICE:
The control unit allows the power supply and the photocells connection.
The intervention during the closing phase causes the inversion of the motion.
The input (MT2: C-D), if not used, must be jumpered.
Before starting the opening or closing, the control unit makes 2 blinking / beep, indicating that the
motor is going to start. If the rolling shutter is open and you push the opening button (in the
transmitter with 2 buttons), the control unit makes an acoustic signal in order to advise the user that
the rolling shutter is completely open.
TERMINAL BOARD 1
4
5
6
7
8
TERMINAL BOARD 2
A
B
C
A 12 Vac 1 W photocell power supply
output.
B 1
2 Vac 1 W photocell power supply
output.
C N.C. safety device input
(Photocell).
D Common GND input.
E (N.O.) open-close command input
(Start).
SR2
D
E