Technical Characteristics - Optimus OF-722ETH Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. TECHNICAL CHARACTERISTICS

Ethernet communication
CAN Bus
VoIP
Input contacts
Output contacts
Audio inputs
Audio outputs
Internal SD memory
Power supply
Consumption
Weight
Finishes
Measurements
Rack units
INPUTS MODULE. TABLE II
Audio inputs
Controls
Input sensitivity
Signal/noise ratio
Frequency response
Input impedance
Indicators
OUTPUTS ZONE MODULE. TABLE III
Audio outputs
Max. Output level
Output impedance
Frequency response (-3dB)
Signal/noise ratio
Controls (Independent for each audio
output)
Indicators
Output contacts
IF-722ETH version 5.0.001
IF-722ETH
2 Ethernet connections (RJ45) A and B for redundant installations. IP Layer 3 & Layer 4
Network.
Speed : 500kbit/s or 33.3kbit/s
SIP RFC3261 protocol.
G711 coding (PCMA and PCMU), G722 and L16.
3 Input contacts on the control module. Configurable NC/NO.
The detection time of the activation pulse of the input contacts is configurable through
the Call Point software (0-50-100-200-300-400-500-1000-1500-2000 milliseconds).
3 Output contacts on the control module. Configurable NC/NO.
1 FAIL relay. Max. DC charge current: 150 mA. Max. DC or AC peak charge voltage:
350V.
1 Front USB 2.0: Output DC: 5V / 0.2A. Supports files in format WAV/MP3/OGG.
2 Audio input de with RJ45 connectors (see table II).
2 Audio outputs. See table III.
16 GB
100-240 VCA primary power supply. 24 VDC secondary power supply.
150 mA (230 Vac)
1.5 A (24 VDC)
5.6 Kg
RAL9005 iron painted black
482.6 (width) x 44 (height) x 430 (depth)
1
2 (RJ45 connectors)
Independent volume potentiometer for each input.
0 dBm /-20 dBm
> 73 dB
50 Hz ~17.5 kHz
1.2 KΩ / 220 KΩ
Power LED indicator.
2 (RJ45 connectors). Transformer balanced outputs.
+4 dBm
600 Ohm
100 Hz - 18 kHz
Better than 80dB
Audio level adjustment volume, bass and treble, or 10-band graphic equalizer (30Hz /
60Hz / 125Hz / 250Hz / 500Hz / 1KHz / 2KHz / 4KHz / 8KHz / 16KHz) controlled through
software.
Power, priority and fail LED indicators.
2 FAIL Contacts. Configured as open collector (Max. 45V/500 mA.).
R+D Department
IP Audio interface
2 inputs / 2 outputs