M.-Nr. 11725550
Included parts
No.
Mat. no.
Designation
1
Peristaltic pump 4x with BrightLogic dispensing pump controller
1
Peristaltic pump 2x
6
Set of hoses
6
Pump head hose
1
Peristaltic pump accessories
12
1/4" quick-action coupling
12
1/4" hose connector, 8 mm
2
M20 x 1.5 cable gland
2
M20 x 1.5 hex nut
30 m
8 mm PVC hose
30
8–16 mm stainless steel hose clip
1
Wiring harness N1-13, N1-16
The Miele "Technical Service Documentation" (TSD) service application is required when carrying out the
maintenance work on the appliance
The safety instructions and warnings in the relevant Technical Service Documentation (TSD) for the appliance type must
be observed.
The work on the appliance must be carried out in accordance with the work instructions.
Risk of electric shock when working on an appliance connected to the mains supply
WARNING
Risk of electric shock when working on an appliance connected to the mains supply.
Even with the appliance switched off, mains voltage may be applied to some components. When the appliance is
connected to the mains supply, mains voltage is present in the appliance interior.
A
Before any service work is commenced, the appliance must be physically disconnected from the mains supply.
A
Carry out suitable measurements to ensure no voltage is present.
Risk of injury due to sharp edges
WARNING
Some components may have sharp edges.
Risk of injury due to sharp edges
A
Protective gloves should be worn and the edge protection (mat. no. 05057680) should be used.
Preparing dispensing pumps
The pump kit is supplied with fittings for wall mounting. Alternatively, the dispensing pumps can also be mounted on a
pump rack, which is available to purchase separately.
A
If there are squeeze hoses on both sides, fit a quick-action coupling to each of them.
A
Apply a thin layer of grease to squeeze hoses before fitting to the peristaltic pumps.
A
Use a suitable sealant (e.g. Loctite SI5331) when screwing hose connections into the membrane pumps.
A
Always use a hose clip to secure the PVC hose to the hose connection.