Descargar Imprimir esta página

Miele BrightLogic APWM047 Instrucciones De Montaje página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
M.-Nr. 11725550
Connecting BrightLogic to the connector box or XCI box
Default access code for BrightLogic dispensing pump controller: 1899
Control element designations on the BrightLogic dispensing pump controller, see Fig. 1:
1. Back
2. Program
3. Up
4. Pump stop
5. Prime
6. See/Jump
7. Test
8. Forward/Accept
9. Down
A
Connect the BrightLogic dispensing pump controller and suction lances as shown in the enclosed wiring diagram.
A
Set all DIP switches (1) on the dispensing pump controller to the ON position, see Fig. 2.
A
Check that the BrightLogic dispensing pump controller is set to relay mode.
Relay mode should be set by default on delivery.
A
Press and hold down the TEST and SEE/JUMP buttons for 2 s.
A
Enter the four-digit access code. Use the UP and DOWN buttons to set each digit and press the FORWARD/
ACCEPT button to confirm.
A
Use the UP and DOWN buttons to select relay mode and press the FORWARD/ACCEPT button to confirm.
A
Check that the dispensing rate is set to 80 % for each of the pumps that is connected.
The dispensing rate should be set to 80 % on delivery.
A
Press the FORWARD/ACCEPT button.
A
Enter the four-digit access code. Use the UP and DOWN buttons to set each digit and press the FORWARD/
ACCEPT button to confirm.
 The
SETTINGS
 screen is displayed.
A
Press the FORWARD/ACCEPT button until the
A
Use the UP and DOWN buttons to set the required speed and press the FORWARD/ACCEPT button to confirm.
 The display jumps to the next pump.
A
Make the setting for all the other pumps.
A
See the model-specific TSD for the settings for the washing machine.
en
cs
Montážní návod BrightLogic
APWM044 souprava membránového čerpadla DOS-WHD1 obsahuje:
Obsažené díly
Počet
č. m.
Název
1
membránové čerpadlo s ovladačem dávkovacích čerpadel BrightLogic
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
PUMP 1 SPEED
screen is displayed.
11 von 62
31.05.2022