i en farge. Skulle LED-en lyse rødt i 2 sekunder og deretter lyse i
regnbuens farger, kunne den ikke koble seg til Z-Wave-nettverket;
Gjenta trinn 6 og 7, kontakt oss for ytterligere støtte hvis nødvendig.
Nano Shutter er nå en del av ditt Z-Wave automasjonssystem. Du
kan konfigurere den og dens automatisering via ditt Z-Wave system.
Vennligst se programvarens brukerhåndbok for nøyaktige instruksjoner.
Merk: Hvis du kommer over andre lednings oppsett, spør om hjelp fra
en profesjonell elektriker eller fra oss.
Declaration of Conformity. Aeotec Limited declares that Nano Shutter
is in compliance with the essential requirements and other relevant
provisions of RED 2014/53/EU, RoHS 2011/65/EU, IEC 62321:2008,
EN 50581:2012 and ErP Directive 2009/125/EC, No 1275/2008
AMENDMENT 801/2013. The full text of the declaration is available
from support.aeotec.com/nanoshutter/doc
Specifications. Z-Wave devices operate between 868.40 & 926.3
MHz depending on local restrictions. It uses up to -2.66 dBm ERP
transmit power, enabling long range connectivity. Full information
on device specifications and certifications at support.aeotec.com/
nanoshutter/specs
Declaración de conformidad. Aeotec Limited declara que el Nano
Shutter está en cumplimiento con los requerimientos esenciales y otras
provisiones relevantes de RED 2014/53/EU, RoHS 2011/65/EU, IEC
62321:2008 y EN 50581:2012. El texto completo de esta declaración
está disponible en support.aeotec.com/nanoshutter/doc
Especificación técnica. Los dispositivos Z-Wave operan entre
868,40 y 926,3 MHz dependiendo de las restricciones locales. Utilizan
40
AC120V~230V
Notes for the wire connection ports:
N – Power input for neutral
L – Power input for live
IN – Input for load power supply
OUT1 – Output for Motor direction 1
OUT2 – Output for Motor direction 2
S1 – External Switch/button 1 control for Motor
S2 – External Switch/button 2 control for Motor
3. Install Nano Shutter to the gang box.
a. Live/Hot wire connection: Connect the Live/Hot
wire to the "L" terminal on Nano Shutter.
b. Neutral wire connection: Connect the Neutral
wire to the "N" terminal on Nano Shutter.
c. Load wire connection: Connect the 2 Load wires
(Motor direction 1 and Motor direction 2) to the
"OUT1" and "OUT2" on Nano Shutter.
WallSwipe
M
Live
Neutral
5