Fitting Instructions Code Handle
ENG
The handle is designed for doors that are 32 to 65 mm
thick, 1¼'' to 2½''. Check that your door fulfils these
requirements before you start installation. The handle
may not be fitted without the attached adaptor plate.
This set is enclosed with a Tubular latch bolt with
!
60 mm (2 ) backset (in some markets 70 mm
(2 ¾) – this MUST be used with the Code Handle in order for
the set to function to specification. Please note if the provided
Tubular Latch bolt is not used all warranty is invalided.
Preparation: Check that all parts are included and make
sure you have the necessary tools, see page 2. Fit the
batteries according to the instructions on page 3. Also
read about batteries in section "Operating Instructions
". The Tubular latch bolt enclosed with
Code Handle
®
the set must be installed according to the instructions
provided. When fitting, use the illustrations provided on
the fold-out at the rear of the manual.
1 Register an administrator's code
The Code Handle must be initiated by deciding an
administrator's code prior to fitting the handle.
The Code Handle does not have an administrator's code
when delivered.
a Hold the handle horizontally with the pin/square shaft
downwards, fig. 1a.
b Hold buttons 1 and 4 pressed at the same time.
The LED flashes red, fig. 1b. Release the buttons.
The LED lights green constantly.
c Enter an administrator's code, 6 digits, fig. 1c.
The LED flashes green rapidly. The entered administrator's
code is now activated.
Note that all user codes are erased if the administrator's
code is changed. It is important that you write down your
administrator's code on page 12 and store it safely. To
change the administrator's code again, repeat the above
procedure.
Operating Instructions Code Handle
Batteries
The ASSA ABLOY Code Handle
®
is delivered with two
CR2 batteries.
BATTERY WARNING! The working life of the batteries
!
is usually at least a couple of years, depending on
the number of Code Handle operations and the performance
of the batteries. If the LED flashes red when you press the
pushbuttons, it's time to change the batteries. In addition,
to accentuate the need to replace batteries, there is a
slight delay in opening at the same time as the LED flashes
red. The Code Handle will remember all codes during battery
replacement.
It is important to choose good quality batteries for
6
8816
®
2 Select appropriate screws
Determine the length of the screws according to the
formula: Screw length = door thickness -5 mm,
3 Turn the square shaft
Turn the square shaft so that one of the flat parts
indicating "UP" is at the top, fig. 3. Hold it in this
position when fitting, as in fig 4a.
4 Positioning the handle
a Position the outer handle (with pushbuttons) on the
door, fig. 4a. Make sure the handle is kept horizontal
throughout fitting.
b Position the inner handle, fig. 4b.
c Screw the inner and outer handles together, fig. 4c.
Make sure that fitting is performed correctly,
so that both handles can move freely and are spring-
loaded upwards.
5 Unlock
Enter at least one user code, see section "Enter new
or change existing user code" under "Operating
Instructions Code Handle".
Unlock the handle by entering a correct code on the
pushbuttons 1 to 4, fig. 5. A correct code causes the LED
to flash green, if the sound is on it is also acknowledged
by three short beeps. An incorrect code causes the LED
to flash red. The handle will remain unlocked once a
correct code has been entered, as long as automatic
locking has not been requested, see section "Automatic
locking" under "Operating Instructions Code Handle".
6 Lock
Lock the handle by pressing the padlock button,
fig. 6. The LED flashes red. If the sound is on, locking
is also confirmed by a beep.
®
replacement. Choose a well-known make of CR2
battery. For battery replacement, follow the instructions
on page 3 and be aware of the safety aspects by:
• Installing the batteries the right way round, fig. 2,
page 3.
• Don't mix new and old batteries, or different makes.
• Replace both batteries at the same time.
• Don't expose batteries to fire.
• Handle discharged batteries responsibly and dispose
of them according to environmental guidelines.
• Batteries should be kept out of the reach of children.
• Batteries should be fitted individually.
Security
If an incorrect code is entered five times consecutively, the
Code Handle will be disabled for 3 minutes and cannot
be opened. The disable can be overridden by entering a
correct code twice consecutively.
User codes
ASSA ABLOY Code Handle can have 9 different user
''.
codes that can be programmed from the selected
administrator's code.
Enter new or change existing user code
1 Enter programming mode by holding the lock
button pressed until the LED lights red constantly.
2 Enter the administrator's code within 5 seconds.
The LED lights green.
3 To register a code, select one of the 9 memory positions
by pressing pushbutton 1 the same number of times as
the memory position; i.e. one depression for memory 1,
two for memory 2, etc.
4 Wait until the LED lights green constantly.
5 Enter the new user code, which can comprise
4, 5 or 6 digits.
6 Wait until the green LED goes out. Your new code
is acknowledged by three short beeps.
7 Other codes can be stored in the remaining
memory positions. Follow the steps 1 - 6 above.
8 To exit programming mode, and confirm your new codes,
press lock button.
NOTE! You can write down your user codes on
page 12.
Remove existing user code:
1 Enter programming mode by holding the lock button
pressed until the LED lights red constantly.
2 Enter the administrator's code within 5 seconds, the LED
lights green.
3 Select which one of the 9 codes to be erased by pressing
pushbutton 1 the same number of times as the memory
position. I.e. one depression for memory 1, two for
memory 2, etc.
4 Wait until the LED lights green constantly.
5 Press the lock button to erase the selected position and
to exit the programming mode. The LED flasches red and
the selected memory position is erased.
6 To erase additional memory positions, repeat the steps
above, and indicate the position to be erased by a
corresponding number of depressions (step 3).
Audio signals
The Code Handle is delivered with the audio signal
enabled, and it can be turned off as follows:
1 Enter programming mode by holding the lock
button pressed until the LED lights red constantly.
IMPORTANT: If the product does not work: Remove the batteries according to the instructions on page 3
and then re-insert them. If the product still does not work, try fitting new batteries of an approved make.
If neither of these solutions work, take the product and associated codes to your dealer.
2 Enter the administrator's code within 5 seconds, the LED
lights green.
3 Press pushbutton 2 once to turn the audio signal off/on.
A low tone indicates that the signal has been turned off
and a high double-tone indicates that the audio signal
has been turned on.
4 Confirm the change and exit programming mode by
pressing the lock button, or wait until the green LED
turns off.
Automatic locking
Auto locking requires that the handle returns to the
horizontal position within 9 seconds of opening.
The Code Handle is delivered in manual mode.
WARNING! In automatic locking mode, the Code
!
Handle will repeatedly attempt to re-lock within 9
seconds from opening. If the handle is not returned to its
horizontal position within this time frame, the handle
will remain unlocked. The effect is similar to the temporary
disabling of auto-locking as described below.
Auto locking can be selected as long as the handle returns
to the horizontal position within 9 seconds of a correct
code being entered. To change the mode, follow the
instructions below:
1 Enter programming mode by holding the lock
button pressed until the LED lights red constantly.
2 Enter the administrator's code within 5 seconds, the LED
lights green.
3 Press pushbutton 3 once to change the mode to/from
automatic locking. The change is confirmed by three
short beeps (On) or a low pitch tone (Off).
4 Confirm the change and exit programming mode by
pressing the lock button, or wait until the green LED
turns off.
Temporary disabling of automatic locking
Enter a correct user code and wait until the LED stops
flashing. Immediately press pushbuttons 1 and 4 at the
same time. The door is now unlocked until the next time
the lock button is pressed or a user code is entered, after
which the handle returns to automatic locking mode.
Resetting the code memory
The Code Handle can be reset to factory settings
by changing the administrator's code, see steps 1-6
Register an administrator's code under
"Fitting instructions Code-lt 8816".
The settings will then be:
• Empty user codes
• Audio signal on
• Auto locking off
7