Troubleshooting - Ebinger TBW Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DE
EN
7. Trouble Shooting
Pump does not start ( LED on pressure sensor lights up green)
Battery empty
Cable / plug defective
Fuse defective
Pump does not start (no LED on pressure sensor lights up)
Fuse defective
Pump / sensor defective
Pump runs, but no water is sucked in
(LED on pressure sensor lights up orange)
No water in the tank
Filter dirty
Suction height too high (max. 3 m filled, 1 m empty)
Leak in the suction line (hose, clamp etc.)
Gear wheels worn
LED on pressure sensor lights up red / blue (pump running or not running)
Error
Error persists
Pump runs, but no power
Battery empty / defective
Gear wheels worn
Pump switches on and off when valve is open
Pressure line too small or too long
LED charge level indicator decreases when switched on and
goes up again when switched off
Normal fluctuation
LED charge level display after charging at 100% and
sharply reduced within a few minutes
Battery worn out
LED charge level indicator after charging only at approx. 85%.
LED display shows wrong value
Charger does not start charging when plugged into the battery
ATTENTION:
In rare cases, it can take up to 24 hours to start charging. If the battery is still not charged, it
is defective and must be replaced.
No LED lights up on the charger when connected to the mains.
Check the fuse of the power supply
Charger is defective
FR
ES
IT
► charge or replace
► replace
► renew
► renew
► renew / repair
► fill
► clean
► adjust height
► remedy the leak
► replace
► carry out restart
► renew pressure sensor
► charge or replace
► replace
► use larger hose Ø
► reduce hose length
► no need for action
► replace
► calibrate LED display (see chapter 9)
► deep discharge the battery
► switch on the charger.
► replace it