3. ELECTRICAL CONNECTIONS
Connect the power supply cable to the mains and the servocontrol pre-wired cable to the auxiliary contact of the
filter box (230 Vca).
1
Wiring diagram:
1. Input Level Probe (Product Tank)
2. Input Frequency signal by Water meter pulse sender
3. RS485 Serial Port (optional)
4. Input Temperature Probe (PT100 sensor not included)
5. Output Relay Auxiliary Pump (Dry contact, Relay 250 Vac 10 A)
6. Output Relay Alarm remote (Dry contact, Relay 250 Vac 10 A)
4. TECHNICAL SPECIFICATIONS
Specifications
Measure range
Set Point range
Alarm range
Accuracy
Resolution
Power supply
Insulation class
Consumption
Pump flow rate
Max. back-pressure
Probe calibration
Pump state
Peristaltic tube
(ID x OD mm)
Dimensions
(H x W x D mm)
Weight
0000138883
2
3
4
PoolMatch pH
rev. 1.0
5
6
Recirculating pump
230V
3.0 ÷ 10.0 pH
6.0 ÷ 8.0 pH
5.0 ÷ 9.0 pH
± 0.04 pH
0.01 pH
230 VAC 50 Hz
1.6 l/h
1.5 bar
Automatic
Proportional dosing
Norprene 4.8 x 8 mm
185 x 124 x 110 mm
1.0 kg
EN
PT100 temperature probe
2 wires
PoolMatch ORP
200 ÷ 999 mV
400 ÷ 850 mV
300 ÷ 900 mV
± 2 mV
1 mV
II
10 W
4
3 wires
3