LIVELINK ENOCEAN GATEWAY
For your safety
Read all instructions and mounting steps carefully. Keep the
instructions for maintenance or disassembly work.
Explanation of the warning levels
Observe and follow the warnings.
Non-observance of the warnings may lead to injuries or materi-
al damage!
WARNING! Indicates dangers which can result in seri-
ous and/or fatal injuries.
CAUTION! Indicates dangers which can result in inju-
ries or health hazards.
NOTICE. Indicates dangers which
can result in material damage or malfunctions.
TIP. Indicates information containing advice or a useful
note.
Explanation of important symbols and pictograms
Indicates professional personnel who are trained and
authorised to carry out the electrical connection.
Indicates professional personnel who are trained and
authorised to carry out the mounting.
6 | 36
10264304 | 220215 | © trilux.com
LIVELINK ENOCEAN GATEWAY
Safety notes
WARNING! Risk of electric shock!
Never work with voltage applied.
NOTICE. Operation permitted only with all-pole
protected supply. Comply with DALI standard in
accordance with IEC 62386.
IImportant notes on control units
• Do not exceed the maximum permissible ambient tempera-
ture ta of the control unit. Exceeding this limit reduces the
service life, and in extreme cases there is a risk of prema-
ture failure of the control unit.
• Lay connection lines ( 1-10V, DALI, etc.) from the DALI con-
trol gear unit to the gateway.
Important note on commissioning
A strain relief for the connection cable must be provided on
site for installation of the device.
Intended use
Intended for indoor use with a maximum ambient temperature
of: ta 65 °C
Safety class: III
Protection rating: IP20