Klein Tools MM720 Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
TEMPERATURE
1. Insert K-type thermocouple with adapter into the V
jacks (observe polarity markings on thermocouple and meter), and
rotate function selector switch
NOTE: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SEL" button
appropriate icon (either °F or °C ) appears on the display.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize. The meter will auto-
range to display the measurement in the most appropriate range.
Remove thermocouple before switching meter to other
measurement functions.
The thermocouple included with the original purchase
is suitable for temperatures below 356°F / 180°C only. To
measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.