RECESS MOUNTING
These instructions are for recess mounting your cabinet. For a surface mount installation, refer to the instructions included with the
surface mount kit (sold separately, see page 4). Before beginning installation, remove and set the door aside in a safe place.
NOTES: Ensure that the cabinet is mounted so that the door has at least 1" (25mm) clearance from the top of the faucet and at least 1"
(25mm) clearance from the ceiling.
1. Remove door from cabinet by taking the hinges off of the mounting plates.
2. Place cabinet in rough-in and check for square, plumb, and level.
Note: Pull electrical wire through the lower electrical hole in cabinet.
3. Install a #10 X 2" screw [SS674] through top mounting hole in cabinet side and screw into wall stud as shown.
Note: Do not over-tighten screws or cabinet box may deform.
4. Once cabinet is installed square, plumb, and level, install #10 X 2" screws into wall studs through the three remaining mounting
holes.
Note: Do not over tighten screws.
1
3
2
4
[SS674]
#10 x 2" #10 X 2" PHILIPS 410
STAINLESS STEEL SCREW
Part no. CB-209-1439 5/10/22
Craft Series Cabinet
© 2022 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376
www.robern.com
6
Installation instructions