53ECO11-W is a device for monitoring power consumption, monitoring self-production by means of
photovoltaic panels and controlling electrical loads within a residential context with single-phase users
(230Vac/50Hz) and power used not exceeding 10kW.
The device envisages the connection of two TA current transformers, one to measure the power and the
energy taken from and/or delivered to the grid (exchange TA) and a second transformer to measure the
power and energy produced by the self-production photovoltaic system (production TA).
Based on parameter programming, the device is able to optimise the excess energy produced by the
photovoltaic system.
The device is also able to control the power consumption of the home, keeping the power taken from
the grid within the set threshold (contractual power of the user) by controlling the "loads" by means of
home automation / IoT actuators: the device connects and/or disconnects the loads following the set
order of priority to keep the maximum power used (set during the configuration phase) within the set
limits, taking into account the power of each load and the power that can still be taken from the meter.
In this way, the device prevents user overload (if several high-consumption appliances are switched on
at the same time), thus avoiding the intervention of the thermal protection of the meter.
Technical specifications
The specifications are described with reference to fig.1:
Mechanical
• Container:
• Dimensions:
• Degree of protection:
• Colour of container:
• Fixing:
• Operating position:
• Terminal boards:
Signalling
• ON signalling LED:
Button
• PRG programming button
Connections
• Insulation stripping:
• Screw:
• Tightening torque:
• Capacity:
• Opening:
• Terminal N:
• Terminal L:
• Terminals 1 and 2:
• Terminal 3:
• Terminal 4:
• Terminal 5:
• Terminals 6 and 7:
• Terminals 8 and 9:
• Terminals 10 and 11:
• Terminals 12 and 13:
Radio specifications
• Wi-Fi 802.11b/g/n
• Access point (AP) Station (STA), B, G, N or mixed mode -mesh network-
Monitoring device specifications
Power and energy measurement
• Manageable system power:
• Measuring range (PATT):
• Resolution (PATT):
• Max metering (EATT):
• Minimum disconnectable load: 100W
• Maximum disconnectable load: <= Manageable system power
Temperature measurement
• Measuring range:
• Resolution:
• Loyalty error:
4 DIN modules
(70 x 89 x 66) mm
IP20 (IP 30D in the special containers)
grey RAL 7016
on EN 50022 DIN rail or directly on the panel, using
the special holes for screws (Ø 4mm max)
vertical
16A-250V
There is a yellow optical signalling light on the front.
6 mm
slotted screwdriver head 3 x 1 mm
0.5 Nm
flex wire 0.14 ÷ 2.5 mm2 (26 ÷ 13 AWG)
rigid wire 0.14 ÷ 4 mm2 (26 ÷ 11 AWG)
2.5 mm x 4 mm
Neutral
Line
Clean contact output for Storage Tank control
Temperature Probe Connection for Storage Tank
PWM for Storage Tank control
GND -common for terminals 3 and 4-
Clean contact input:
Storage Tank management consent.
Clean contact input:
Storage Tank management consent.
Exchange TA connection (pay attention to the direction
indicated on the wiring diagram and to the arrow on the TA.
Terminal 10 white - Terminal 11 black)
Production TA connection (pay attention to the direction
indicated on the wiring diagram and to the arrow on the TA.
Terminal 12 white - Terminal 13 black)
from 1.0 to 10.0kW in 0.1kW steps
from 0 to 10 kW
10 W
6.55 MWh
from 0°C to +90°C
1°C
2°C max
Power supply voltage
• Rated voltage:
• Tolerance:
• Maximum power consumption:
Weather conditions
• Overvoltage category:
• Reference Temperature and Relative Humidity:
• Operating Environment Temperature Range:
• Level of pollution:
• Maximum Relative Humidity:
• Max altitude:
Rated load / electrical life
• Resistive load (cosϕ 1):
Duration: 0.5s ON 1.5s OFF at room temperature 20000 cycles
• Incandescent load: max. 10A @ 250VAC
Duration: 0.5s ON 1.5s OFF at room temperature 20000 cycles
• Engine load:
Duration: 0.5s ON 1.5s OFF at room temperature 20000 cycles
• Capacitative load:
Duration: 0.5s ON 1.5s OFF at room temperature 5000 cycles
Protections
Overload and short-circuit protection
Insert a 1.5kA (min) C16 circuit breaker in series with the circuit.
Overtemperature safety protection
PTC resettable thermal fuse built into the appliance. It trips when there are internal faults that may
lead to dangerous overtemperatures.
Installation and Maintenance Rules
Installation and maintenance operations must be performed by qualified personnel in compliance
with the regulations governing the installation and maintenance of electrical equipment in force in the
country where the products are installed.
- Before working on the system, disconnect it by switching off the main switch (symbol
- This device complies with the reference Standard, in terms of electrical safety, when it is installed in
the relative control unit.
- If this device is used for purposes not specified by the manufacturer, the protection provided may be
compromised.
- Observe the maximum current and voltage values specified for the device
- The mains supply circuit must be protected against overloads by a device, fuse or circuit breaker, with
a rated current not exceeding 16 A, that can be easily identified and reached.
Regulatory compliance
• Radio Equipment Directive (RED). RoHS Directive.
• Low Voltage Directive (LVD). Standards EN61010-1, EN_61010-2-030.
• EMC Directive. Standards EN 61000-6-1, EN 6100-6-3.
AVE SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text of the EU
Declaration of Conformity can be found in the product data sheet at the following address: www.ave.it.
WEEE - Information for users
The crossed-out bin symbol on the appliance or on its packaging indicates that, at the end of
its life, the product must be collected separately from other waste. The user must therefore deliver
the equipment to appropriate separate collection centres for electrotechnical and electronic waste.
Alternatively, the equipment can be handed over, free of charge, to the distributer when a new piece of
equivalent equipment is purchased. At distributors of electronic products with a sales area of at least
400 m
2
it is also possible to hand over, free of charge, electronic products smaller than 25 cm, without having
to purchase new equipment. An efficient separate waste collection leading to the subsequent recycling
of the disused appliance, or disposal compatible with the environment contributes to avoiding negative
effects on the environment and health and favours the re-use and/or recycling of the materials which
the components of the appliance are made of.
120-230V~ 50-60Hz
±10%
3.5W with relay energised
II
25°C RH 65%
from -5°C to +35°C (Indoor)
2
90% at 35°C
2000 m a.s.l.
16A @ 250VAC
ON = 60A 250VAC cosϕ 0.65 300ms +
10A 250Vac cosϕ 0.65 200ms (300ms +
200ms = 0.5s ON )
2.5Ohm + 140uF in parallel with
10A 250VAC cosϕ 0.9
).