Other interconnected alarms in the network will receive the signal after few seconds, and
they will beep continuously without LED flashes.
Reset Connection
a)
Remove the product out of the back plate, and you will hear a beep in few seconds.
b)
3x Press the test/silence button and press once again when LED light turn on.
c)
While the LED light turn off with a beep, the connection has been reset successfully.
How to silence interconnected alarms
When an interconnected alarm has been activated, find the originating interconnected alarm, which will be the one
both emitting the audio signal and red LED message. Mute this interconnected alarm by pressing its test/silence
button, and within 40s the remaining interconnected alarms will go back to standby.
Note: if you press the test/silence button on one of the interconnected alarm other than the
originating alarm, it will NOT be silenced, the remaining interconnected alarms will continue
emitting sound until the primary alarm is stopped.
11. Maintenance
This smoke alarm is equipped with a self-testing mechanism. Additionally, we recommend testing the smoke alarm
manually at least once per months by pressing the test/silence button. If the smoke alarm functions correctly, it
will generate a loud beep. Due to the loudness of the alarm, make sure that you always stand at arm's length
distance from the unit when testing. If the smoke alarm does not generate the acoustic signal, it must be replaced
immediately. Clean the smoke alarm at least once per month to remove dirt, dust or debris. Use a vacuum cleaner
with a soft brush and vacuum all sides of the alarm. Do not remove the top cover to clean it inside. The alarm does
not contain any serviceable parts inside – do not attempt to open or repair it. If the alarm shows any signs of
damage, it must be replaced.
12. Warnings
This Smoke alarm is for indoor use only. To prevent injury, this smoke alarm must be securely attached to a
ceiling/wall in accordance with the installation instructions. Do not paint or cover the Smoke alarm.
This Smoke alarm should not be exposed to excessive heat such as sunshine, fire, etc. Do not test with flame – this
can set fire to the Smoke alarm and damage the house. Do not test with smoke, as the results can be misleading,
unless special equipment is used. Prolonged exposure to low or high temperatures, or high humidity, may reduce
battery life. Prolonged periods of alarm will reduce battery life. The latest design, materials and manufacturing
techniques have been used in the construction of this Smoke alarm to minimize the risk of its contamination by
dust, insects, etc. However, it is impossible to completely eliminate such risk, so ensure that the Smoke alarm is
clean, and dust does not build up. Any insects or cobwebs in the vicinity of the Smoke alarm should be promptly
removed. In certain circumstances, even with regular cleaning, contamination can build up in the sensor, triggering
the alarm. If this happens, the Smoke alarm must be replaced.