4. Preparation
Switch position
Mode
Timer enabled
Continuous operation (timer
disabled)
5. Settings
•
Align the marking arrow with the current
Setting time:
time (turn dial clockwise) (Fig.
• Then plug the ground spike with a mechanical timer into
a suitable electrical outlet. The dial rotates once every
24 hours. The arrowhead points at the current time.
•
When the built-in timer is unplugged, it stops
Note:
running. The timer must be reset after it has been
stopped.
•
Setting turn-on and turn-off time:
switching pins on the timer, each corresponding to
a 15-minute interval. For example, if you want the
appliances connected to the product to turn on daily
from 5:30 PM to 7:00 PM, push the corresponding
switching pins down until they click into place (see
switching pins highlighted in grey in Fig.
6. Operation
• Plug the appliances you need to use to the socket
outlet(s) of the ground spike.
7. Cleaning
• Disconnect the device from the power source before
cleaning.
• Use a soft, lint-free cloth for cleaning. When heavily
soiled, clean the device with a damp cloth or sponge.
Ensure all parts are perfectly dry before reconnecting
the device to a power supply!
• Never use abrasives or solvents for cleaning!
• The device must not be exposed to acids or substances
containing acid and/or substances containing salt.
8. Technical Data
Power supply:
Rated voltage:
Power consumption:
Rated current:
IP rating:
9. Disposal Information
).
There are 96
).
22
230 V ~
230 V ~ , 50 Hz
max. 3500 W
16(2) A
IP44
This symbol indicates that this product must not
be disposed of with normal household waste
within the EU. The device should be recycled
as per applicable environmental regulations to
prevent potential damage to the environment from
uncontrolled waste disposal and to promote the
sustainable reuse of material resources. Return
your old appliance to an appropriate collection
point or contact the dealer where you purchased
the product.