Declaration Of Performance - Palram CANOPIA PALERMO 4.3x4.3 Instrucciones De Montaje

Tabla de contenido

Publicidad

Palram Canopia Ltd.
Teradion Industrial Park, M.P Misgav 2017400, P.O.B 53, Israel
Tel +972.4.848.6900 | Fax +972.4.848.6901
canopia@palram.com | www.canopia.com
According to Construction Products Council Directive UE N°305/2011 and EN 14963:2006
Identification code: Palermo™ 4300, refer to CE label no 045
1.
2. Type: A light transmitting self-supporting Twin-wall PC roofing structure with upstand made of aluminum
and galvanized steel elements
3. Intended use: open multi-purpose covering where the ground slope is less then 5%
4. Manufacturer: Palram Canopia Ltd. Teradion Industrial Park, M.P Misgav 2017400, P.O.B. 53, Israel
5. Importer and EU representative : PALRAM Applications UK, Unit 40 J3 Industrial Estate Carr Hill,
Doncaster DN4 8DE
6. Assessment and verification of constancy of performance: System 3
7. Declared performance:
Resistance to upward load: UL 400
Resistance to downward loads: DL 500
Reaction to fire: B, s1, d0
For mounting and fixing provisions see EN 16153:2013
Resistance to fire: NPD
External fire performance: F
Water tightness:
For the rooflight with upstand: Pass
For the sheet material: Pass
Impact resistance:
For the small hard body: Pass
For the large soft body: NPD
Thermal transmittance:
For the rooflight: NPD (not relevant to an open multi purpose cover)
For the sheet material: 3.60 W/(m²•K)
Direct airborne sound insulation: NPD (not relevant to an open multi purpose cover)
Radiation transmittance:
- Light transmittance: Tv - 41.46%
- Solar direct transmittance: Te - 43.6%
- Solar factor: g value - 0.58
Air permeability:
For the rooflight: NPD (not relevant to an open multi purpose cover)
For the sheet material: Pass
Durability (of the sheet material): ΔA, Cu 1, Ku 1
8. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 7.
This declaration of performance is issued, in accordance with Annex ZA.2.2 – EN 14963:2006,
under the sole responsibility of Palram Canopia Ltd.
ITT reports and Factory Production Control records are available upon request at www.canopia.com
Signed for and behalf of Palram Canopia Ltd. by:
Teradion Industrial Park, Misgav,

Declaration of Performance

Issue Date 04/05/2017
ROOF
04.05.2017

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Canopia palermo 14x14

Tabla de contenido