- Screw the cap (8B) to its o-ring (8C) to point marked "CLEAN".
- WARNING: the gap between the spring and the water surface must not be greater than 1m.
The filter is now ready to use. Simply switch on the pump and connect the UV-C lamp's power supply cable.
Caution
Temporarily suspend the use of the UV sterilizer if treating either water or fish.
- If the capacity of pump is higher than what is specified on the table, use a 2-way valve to regulate flow.
Sect. 4 Maintenance
Clean filter regularly.
If the water flow decreases, clean both filter and pump.
The filter is equipped with a quick cleaning system called "Back Wash".
- Always turn off the pump before acting on the valve.
- Connect flexible tube to black adjustable hose marked "CLEAN" - 8A; replace cap (8B); direct tube away from
pool. The water can be used to irrigate garden.
- Turn on pump again. Rotate handle from working position (fig. A) to cleaning position (fig. B).
- Let water flow until it becomes clear.
- Place handle back on working position.
- When pump is off, remove the additional tube and put the cap back in place (8B). Twice yearly, clean the filter
completely and internally.
- Turn off filter and open lid.
- Clean the inside.
- Rinse the sponges and bio-balls in tank with pond water (do not use tap water). Replace the sponges if damaged
or worn.
Do not use solvents or cleaning agents to clean filter and filtering components. Use pond water only.
If algae formation increases, verify that UV-C appliance is working properly.
To ensure maximum efficiency, UV-C lamp (7) should be replaced after 5000 working hours. If lamp is working
properly, clean quartz tube in which it is placed.
Before attempting any maintenance, unplug any appliances immersed in pond from the power source.
- Check that pump and lamp's power supply are off.
- Turn handle (3) onto working position.
- Remove lid (1) and screw (2).
- Lift handle (3) and remove screws (4).
- Lift lamp socket (5) being careful not to lose o-ring (10). - Do not pull power cable.
- Clean quartz glass tube (9); remove any lime scale deposits with decaling agents.
To replace lamp:
- Extract tube (9) from socket (5) pulling gently.
- Replace lamp (7).
- Check that components are dry.
-Place tube (9) back into socket (5); check that o-rings (6) are undamaged and properly repositioned.
- Mount o-ring (10) on socket (5); insert both in lid (11).
- Turn on lamp to verify that it is functioning. Light will be seen in transparency.
- Tighten screws (4), mount handle (3) by placing it in working position.
- Tighten screw (2) and mount lid (1).
Sect. 5 – Warranty
The present device was manufactured and inspected according to the latest methods. The seller warrants for faultless
material and workmanship in accordance with the legal regulations of the country in which the device was purchased.
The warranty period begins with the day of the purchase and is subject to the provisions below:
Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will be
eliminated free of charge. Any complaints are to be reported immediately upon their detection.
The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties.
Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection or
installation or Acts of God or other external influences are excluded from warranty.
Parts subject to wear, such as the UV bulb and filter mats are excluded from the guarantee.
All parts were manufactured using maximum care and high-quality materials and are designed for a long lifecycle. It
should be understood, however, that the wear and tear depends on the kind of use, the intensity of use and the
internals of maintenance.
25