ControlCenter CV41 4-to-1 Converter
Use the ControlCenter CV41 4-to-1 converter to create a single home run connection back to a PowerShare PS602, PS404A, or
PS604A amplifier when multiple CC-1 zone controllers are distributed throughout an installation. Connect each zone controller to the
CV41 converter using CAT 5 cables with RJ-45 connectors, then run a single CAT 5 cable from the CV41 converter to the amplifier.
For more information, see the ControlCenter Zone Controllers Installation and Operation Guide.
CV41 Converter Diagram
Top View
Bottom View
Connecting the CV41 Converter
Connect up to two CC-1 zone controllers to a PS602 amplifier, as shown below. If
the two CC-1 zone controllers are ganged together first, then the CV41 converter
is not required.
CAT 5 cable
7.6 m (25 ft) max
SIGNAL
POWER
1
2
LIMIT
PowerShare
Adaptable Power Ampli er
Left Side View
CAT 5 cable
609 m (2000 ft) max
PS602
27 mm
1.1 in
Right Side View
Connect up to four CC-1 zone controllers to a PS404A or PS604A amplifier, as
shown below. You can also gang any combination of CC-1 zone controllers together
first, then use the CV41 converter to create a single home run to the amplifier. All
inputs on the CV41 converter are identical, so any input combination is acceptable.
CAT 5 cable
7.6 m (25 ft) max
SIGNAL
POWER
1
2
3
LIMIT
PowerShare
Adaptable Power Ampli er
All trademarks are the property of their respective owners
CAT 5 cable
609 m (2000 ft) max
4
PS604A
©2022 Bose Corporation, All rights reserved.
Framingham, MA 01701-9168 USA
www.pro.Bose.com
AM771894 Rev. 02
April 2022
pro.Bose.com