OPERATION
AC Applications
Before connecting an appliance or power cord to the generator:
Make sure that it is in good working order. Faulty appliances or Power cords can create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately. Disconnect the
appliance and determine whether the problem is the appliance or the rated load capacity of the generator has been
exceeded.
Make sure that the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed the
maximum power rating of the generator. Power levels between rated and maximum may be used for no more than 30
minutes.
NOTICE
Substantial overloading will open the circuit breaker. Exceeding the time limit for maximum power operation or slightly
overloading the generator may not switch the circuit breaker OFF but will shorten the service life of the generator.
Limit operation requiring maximum power to 30 minutes.
For continuous operation (longer than 30 minutes), do not exceed the rated power.
50