5.3.5 Overload protection
In case of a power outage, to protect the compressor, there is a delay of 3 minutes until
the compressor restarts.
5.4 DRAINAGE
Manuel drainage
The machine stops automatically when the water tank is full. Remove the plug from the
power outlet.
Note: Move the device carefully to prevent water from flowing.
Place a water tank under the water outlet on the side of the box.
Remove the lid and the water will automatically drain into the container.
Note 1:
1. Keep the drain plug in a safe place.
2. The box can be tilted slightly back when draining.
3. Make sure the collection tray is large enough to collect the contents.
4. When the water has drained completely, put the lid and drain hatch back in place.
Continuous drainage
The self-evaporation system uses the collected water to cool the condenser banks for
better performance. The condensate tank does not need to be emptied in cooling mode.
Note that it should be emptied in heating and drying mode and in case of high humidity.
Condensation water evaporates into the condenser and is evacuated through the
exhaust pipe. For continuous or unattended operation in drying and heating mode,
connect the supplied drain hose to the unit.