WARNING
Risk of crushing if the load capacity of
the wall is exceeded
If the load capacity of the wall is
exceeded, the carrying device and the
unit can detach from the wall.
Before installation, calculate the load
n
capacity and statics of the wall on
which the unit will be mounted.
Secure the unit to the wall fixture of
n
the wall mounting using the safety
plates.
Weight and forces to calculate the load
capacity of the wall
Weight in kg [lbs]
Total weight at the centre of
gravity (unit, wall mounting,
food etc.)
Forces in N
Pulling force on mounting on
each side (left and right)
Weight force on mounting
on each side (left and right)

4.1 Prepare installation wall

a
The required minimum clearances
from the unit are observed. Take this
from the original installation manual
for the unit.
a
The cardboard template for the wall
unit is ready for use.
1. Attach the cardboard template hori-
zontally to the intended position on
the wall. Note the working height of
the unit. Remove this from the tem-
plate [
Image
2. Mark the 4 holes to attach the right
and left wall panel to the wall.
12 / 84
L
XL
400
540
[88
[11
2]
91]
L
XL
2700
3700
2100
2900
03].
80.51.902_iVario-iVario Pro L_XL_Wall mounting_V01_EU-west
3. Drill 8 holes in total to accommodate
M12 screws.
>>
There are 8 holes in the wall for the
wall fixture.

4.2 Mounting the wall fixture

Mounting the wall fixture on the wall
a
The 8 holes for the wall fixture have
been put in the wall.
a
The right and left wall panels are ready
for use [
Image
a
Suitable fastening material, e.g. 8 M12
heavy-duty anchors are ready for use.
These are not included in the scope of
delivery.
a
2 M10x40 hexagon screws are ready
for use.
a
A torque wrench (50 Nm) is ready for
use.
1. Attach the wall panels to the wall, e.g.
with 4 M12 heavy-duty anchors each.
2. Screw 1 M10x40 hexagon screw each
to the bottom of the wall panels
[
Image
05].
>
The wall panels are attached to the
wall.
Mounting the wall fixture on the unit
NOTICE
Fastening threads can be damaged
If you drill the holes for the hook plates
on the back of the electrical
compartment into the metal sheet, the
fastening thread can be damaged. This
is located directly behind the metal
sheet.
Pay attention to a maximum drilling
n
depth of 2 mm [2/25 inches].