3. Hold the spirit level in the transverse
direction on the underside of the
unit[
Image
rizontal alignment of the unit.
4. Align the unit using the left and right
alignment screws on the hook plates
on the unit.
5. Hold the spirit level lengthways on the
bottom left of the unit
[
Image
10.3], to check the align-
ment of the unit to the wall.
6. Align the unit with the left alignment
screw on the wall panel.
7. Check on all sides if the unit is level
and adjust the alignment screws if re-
quired.
>>
The unit is level with the wall.

4.5 Mounting safety plates

a
The unit is level.
a
The safety plates and 4 M8x20
hexagon socket screws are ready for
use.
a
The 2 cover caps are ready for use.
1. Mount the safety plates with 2 M8x20
hexagon socket screws on each side
on the underside of the unit
[
Image
11].
2. Mount the cover caps on the top of the
covering panel.
>>
The safety plates and cover caps are
installed.

4.6 Check the levelling

a
The unit is mounted on the wall in the
wall fixture.
a
The unit is connected to the mains.
a
The top panel is opened.
14 / 84
10.2], to check the ho-
80.51.902_iVario-iVario Pro L_XL_Wall mounting_V01_EU-west
1. Place the spirit level on the pan bot-
tom in the transverse and longitudinal
directions and check the horizontal
alignment.
2. Align the unit horizontally as described
in this manual.
>>
The levelling has been checked.