Technical Data - monzana MZPP14 Manual Del Usuario

Ocultar thumbs Ver también para MZPP14:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
TROUBLESHOOTING
Problem
Pump with no action
Pump works audibly,
but
no
water
flowing
Low flow rate
Pump stops suddenly
Sand in pool water
More sand in water
Heightened pressure

TECHNICAL DATA

Item number
Mains voltage
Max. power
Protection
category
Protection class
Max. delivery rate
Sand
filling
quantity
(not
included
in
delivery)
Connection cable
length
Total weight
Tank volumes
Possible cause
No power available
Air in system (pump/tank)
is
Hoses kinked, pump is taking
in air
Suction
height
incorrect suction hose
Suction/delivery
exceeded
Valve/hose/filter dirty
Overheating has triggered the
thermal switch
Fresh sand in filter
Incorrect quartz sand used
Blockage
High contamination
100938
106833
220–240 V
220–240 V
~50 Hz
~50 Hz
450W
450W
IPX5
IPX5
I
I
10200 l/h
9960 l/h
20kg
20kg
1.8m
1.8m
9kg
9kg
25L
25L
Solution
Insert plug or check fuses if
necessary
Ventilate the pump as described
and if necessary also the tank.
Check and, if necessary, correct
and seal straightened connections.
Possible hose leak
too
high,
Adjust the position of the pump
Use vacuum-safe suction hose
height
Adjust
pump/system
Check and clean if necessary Use a
vacuum-safe suction hose
wait approx. 30 minutes
use vacuum-safe suction hose
check clogged pipes
This is normal when fresh sand is
being used. Proceed as described.
It will settle of its own accord.
Sand too fine, purchase coarser
sand from a specialist dealer
Cleaning
Cleaning and rinsing
106834
106835
220–240 V
220–240 V
~50 Hz
~50 Hz
450W
550W
IPX5
IPX5
I
I
9960 l/h
10980 l/h
27kg
27kg
1.8m
1.8m
12.8kg
12.8kg
30L
30L
19
the
position
of
994615
220–240 V
~50 Hz
600W
IPX5
I
15900 l/h
50kg max.
1.8m
23kg
60L
www.DEUBAXXL.de
the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mzpp15Mzpp28Mzpp27100938106833106834 ... Mostrar todo

Tabla de contenido