Important - GE PP9830 Manual Del Propietario E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION PREPARATION (Cont.)
6. BLOWER TO DUCTWORK ALIGNMENT
In general, the use of flexible ducting is discouraged
because it can cause severely restricted airflow.
However, if the blower outlet and the floor or wall
duct location do NOT align well, then flexible
METAL ducting can be used to adapt to an offset.
Good alignment without use of flexible ducting is best.
NOTE:
to eliminate as much of the corrugation as possible.
7. PREPARE FOR DUCTWORK
in a variety of ways depending on the kitchen layout.
IMPORTANT: The downdraft air discharge outlet
accordingly.
Typical duct arrangement countertop series.
Inside wall
cabinet
overhang
Peninsula or island
To maximize the ventilation performance of the vent
system:
1. Minimize the duct run length and number of
transitions and elbows.
2. Maintain a constant duct size.
3. Seal all joints with duct tape to prevent any leaks.
49-2001160 Rev. 0
Installation Instructions
Outside
wall cabinet
Peninsula
Through cabinet toe space
6" Max.
Centerline
to
Centerline
Offset
available at your local building supply store.
NOTE: Illustrations are for planning purposes only.
If needed, install any make up (replacement) air
system in accordance with local building code
requirements. Visit GEAppliances.com for available
makeup air solutions.
• Optional duct arrangement under concrete slab.
PVC duct should be used if installing under a poured
concrete slab.
NOTE: PVC sewer pipe type PSM 12454-B
Schedule 40 ASTM D1785.
6" (15 cm)
Dia. 90°
Metal Elbow
Wall Cap
6" (15 cm) Dia.
Metal Duct
12"
(30 cm)
Min.
6"
(15 cm)
Dia. PVC
Coupling
6" (15 cm) Dia.
Pack tightly with gravel
PVC Sewer Pipe
or sand completely
Elbow
around pipe
• Install ductwork so the piece of duct nearest the
downdraft unit slots INTO the next piece of the duct.
Secure the joints with self-tapping screws and apply
duct tape around the joints to ensure an airtight seal.
Air
Flow
Screw
(Requires 3
1 4
" x 10")
3-1/4" x 10" Rectangular
to 6" Round Transition
6" (15 cm)
Dia. Metal
Duct
Concrete
Slab
16"
6" (15 cm)
(40.6 cm)
Dia. PVC
Max.
Sewer Pipe
6"
(15 cm)
Dia.
PVC
Coupling
30'-0" (9.14 m) Max.
6" (15 cm)
Dia. PVC
Sewer
Pipe
6" (15 cm) Dia.
PVC Sewer Pipe
Elbow
Duct Tape
Over Seam and Screw
19

Publicidad

Tabla de contenido
loading

Tabla de contenido